파트넘버.co.kr V23086-R1802-A803 데이터시트 PDF


V23086-R1802-A803 반도체 회로 부품 판매점

PCB Single Relays



Tyco 로고
Tyco
V23086-R1802-A803 데이터시트, 핀배열, 회로
Automotive Relays
PCB Single Relays
Micro Relay K (THT – THR)
n Small power relay
n Limiting continuous current 30A
n Low weight
n Low noise operation
n Wave (THT) and reflow (THR/pin-in-paste) solderable versions
Typical applications
Car alarm, door control, door lock, heated front/rear screen, immobilizer,
lamps front/rear/fog light, interior lights, seat control, sun roof, window
lifter, wiper control.
Contact Data
Typical applications
Contact arrangement
Rated voltage
Rated current
Limiting continuous current
23°C
85°C
Limiting making current
Limiting breaking current
Contact material
Min. recommended contact load
Initial voltage drop at 10A, typ./max.
Operate/release time
Electrical enduranc
cyclic temperature -40°C, +25°C, +85°C
form C contact (CO) at 14VDC
Resistive/inductive load
V23086-*1*01-A403
1 form C, 1 CO
12VDC
NO/NC
30/25A
30/25A
20/15A
40A1)
30A
motor reverse blocked,
25A, 0.77mH
>1x105 ops.
form A contact (NO) at 14VDC
resistive 20A
>3x105 ops.
Wiper load
V23086-*1*02-A803
1 form C, 1 CO
10VDC
NO/NC
30/25A
30/25A
20/15A
40A1)
30A
AgSnO2
1A at 5VDC3)
30/300mV
typ. 3/1.5ms4)
wiper,
25A make/5A break,
generator peak,
20A on NC,1mH
>1x106 ops.
Mechanical endurance
>5x106 ops.
086C/R1_fcw1b
Resistive/inductive load
V23086-*1*01-A402
1 form A, 1 NO
12VDC
30A
30A
20A
40A1)
30A
Lamp load5)
V23086-*1*51-A502
1 form A, 1 NO
12VDC
30A
30A
20A
100A2)
30A
resistive 20A
>3x105 ops.
lamp 100A inrush,
10A steady state
>1x105 ops.5)
Max. DC load breaking capacity
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages. For a load current duration of maximum
3s for a make/break ratio of 1:10.
2) Corresponds to the peak inrush current on initial actuation (cold filament).
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) Measured at nominal voltage without coil suppression unit. A low resistive suppression
device in parallel to the relay coil increases the release time and reducesthe lifetime
caused by increased erosion and/or higher risk of contact tack welding.
5) Be aware of using right polarity, see Terminal Assignment. Wrong polarity will reduce
endurance.
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
10-2013, Rev. 1013
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
http://www.Datasheet4U.com


V23086-R1802-A803 데이터시트, 핀배열, 회로
Automotive Relays
PCB Single Relays
Micro Relay K (THT – THR) (Continued)
Coil Data
Rated coil voltage
12VDC
Coil versions, DC coil
Coil
Rated
Operate Release
Coil Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%
mW
001/801 12
6.9 1.5 254 0567
002/802 10
5.7
1.25
181
0552
051/851 10
6.5 1.1 90 1111
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil operating range
300
250 Umax
200
150
100
50 Uop (E=0V)
0
-40 -20
0
20 40 608 01
Ambient temperature in °C
Does not take into account the temperature rise due to the contact current
E = pre-energization
00
120
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
500VACrms
500VACrms
Other Data
EU RoHS/ELV compliance
compliant
Ambient temperature, DC coil
-40 to +105°C
Cold storage, IEC 60068-2-1
1000h; -40°C
Dry heat, IEC 60068-2-2
1000h; +125°C
Climatic cycling with condensation,
EN ISO 6988
20 cycles, storage 8/16h
Temperature cycling (shock),
IEC 60068-2-14, Na
100 cycles; -40/+125°C
Temperature cycling,
IEC 60068-2-14, Nb
35 cycles; -40/+125°C
Damp heat cyclic,
IEC 60068-2-30, Db, variant 1
6 cycles 25°C/55°C/93%RH
Damp heat constant,
IEC 60068-2-3 method Ca
56 days 40°C/95%RH
Degree of protection
THT:
RT III (61810), IP67 (IEC 60529)
THR:
RT II (61810), IP56 (IEC 60529)
Sealing test, IEC 60068-2-17: THT
Qc, method 2, 1min, 70°C
Corrosive gas
IEC 60068-2-42
10 days
IEC 60068-2-43
10 days
Vibration resistance (functional)
IEC 60068-2-6 (sine sweep)
10 to 500Hz; 6g6)
Shock resistance (functional)
IEC 60068-2-27 (half sine)
6ms, up to 30g6)
Terminal type
PCB:THT, THR
Weight
approx. 4g (0.14oz)
Solderability (aging 3: 4h/155°C) THT
IEC 60068-2-20
Ta, method 1, hot dip 5s, 215°C
Solderability THR
IEC60068-2-58
hot dip 5s 245°C
Resistance to soldering heat THT
IEC 60068-2-20
Tb, method 1A, hot dip 10s,
260°C with thermal screen
Resistance to soldering heat THR
IEC 60068-2-58
260°C; preheating min 130°C
Storage conditions
according IEC 6006887)
Packaging unit
2000 pcs.
6) Depending on mounting position: no change in the switching state >10μs.
7) For general storage and processing recommendations please refer to our Application
Notes and especially to Storage in the Definitions or at http://relays.te.com/appnotes/
2
10-2013, Rev. 1013
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.




PDF 파일 내의 페이지 : 총 5 페이지

제조업체: Tyco

( tyco )

V23086-R1802-A803 relay

데이터시트 다운로드
:

[ V23086-R1802-A803.PDF ]

[ V23086-R1802-A803 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


V23086-R1802-A803

PCB Single Relays - Tyco