MCC |
www.DataSheet4U.com
MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
MP4005W
THRU
MP4010W
Features
• Mounting Hole For #8 Screw
• Plastic Case with Metal Bottom
• Any Mounting Position
• Surge Rating Of 400 Amps
40 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Maximum Ratings
• Operating Temperature: -50°C to +150°C
• Storage Temperature: -50°C to +150°C
MCC
Catalog
Number
Device
Marking
MP4005W MP4005W
MP401W MP401W
MP402W MP402W
MP404W MP404W
MP406W MP406W
MP408W MP408W
MP4010W MP4010W
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
IF(AV)
40.0A TJ = 55°C
Peak Forward Surge
Current
IFSM
400A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
VF 1.2V IFM = 20A per
element;
Maximum DC
TJ = 25°C*
Reverse Current At IR 10µA TJ = 25°C
Rated DC Blocking
1.0mA TJ = 100°C
Voltage
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
MP-50W
B
C
E
D
IG
AC +
D
AC
-
A
H
I
A
DIMENSIONS
INCHES
DIM MIN
MAX
A
1.118
1.130
B .432 .442
C .769
---
D .673 .752
E .038 .042
G .193
---
H .429 .468
i .169 .236
MM
MIN
28.40
10.97
19.53
17.10
.97
4.90
10.90
4.30
MAX
28.70
11.23
---
19.10
1.07
---
11.90
6.00
NOTE
4PL/TYP
∅
Revision: 5
www.mccsemi.com
2004/06/21
MP4005W thru MP4010W
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
Amps 1
.6
.4
25°C
.2
.1
.06
.04
.02
.01
.2 .4 .6 .8 1.0 1.2 1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Forward Derating Curve
60
50
40
30
Amps
20
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
00 25 50 75 100 150 175
°C
Average Forward Rectified Current - Amperesversus
Ambient Temperature -°C
MCC
TM
Figure 2
Micro Commercial Components
Typical Reverse Characteristics
10
6
4
2
TJ=25°C
1
.6
.4
.2
µAmps .1
.06
.04
.02
.01
.006
.00
4
.002
.001
20 40 60 80 100 120 140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 4
Peak Forward Surge Current
600
500
400
300
Amps
200
100
0
12
4 6 8 10 20
Cycles
40 60 80 100
00
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Revision: 5
www.mccsemi.com
2004/06/21
|