Powerex Power |
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM75RVA060
Intellimod™ Module
Three Phase + Brake
IGBT Inverter Output
75 Amperes/600 Volts
TERMINAL CODE
1. WFO
2. VWPC
3. WP
4. VWP1
5. VFO
6. VVPC
7. VP
8. VVP1
9. UFO
10. VUPC
11. UP
12. VUP1
13. Br
14. FO
15. VNC
16. VN1
17. UN
18. VN
19. WN
A
PD
NJ
TYP.
N PB
M
1234
BKE
5678
9 10 1112
L - TYP.
13 14 15 16
17 18 19
P
R
U
UV
CCØ
(4 PLACES)
BB SQ PIN - TYP.
(19 PLACES)
AA - TYP.
Z - TYP.
CY
U VW M
T (4 TYP.)
S NUTS (6 TYP.)
X W SEE
DETAIL A
H
G
DETAIL A
F
RfO
GND FO
IN VCC
GND OUT
Si
GND FO
IN VCC
TEMP
GND OUT
Si
TH
GND FO
IN VCC
GND OUT
Si
GND FO
IN VCC
GND OUT
Si
GND FO
IN VCC
GND OUT
Si
GND FO
IN VCC
GND OUT
Si
GND FO
IN VCC
GND OUT
Si
RfO = 1.5k OHM
B
N W V UP
Outline Drawing and Circuit Diagram
Dimensions Inches
Millimeters
A 4.33 110.0
B 3.50 89.0
C 0.87 +0.04/-0.02 22.0 +1.0/-0.5
D 3.74±0.010 95.0±0.25
E 2.91±0.010 74.0±0.25
F 0.16
4.0
G 0.87 22.0
H 0.42 10.6
J 0.79 20.0
K
2.99±0.02
76.0±0.5
L 0.39 10.0
M 0.49 12.5
N 0.67 17.0
Dimensions Inches
P 0.30
R 0.65
S M5 Metric
T 0.22 Dia.
U 0.56±0.010
V 1.72±0.012
W 0.57±0.012
X 2.90
Y 0.78
Z 0.10±0.010
AA 0.137±0.010
BB 0.02 SQ
CC 0.12 +0.04/-0.02
Millimeters
7.5
16.5
M5
Dia. 5.5
14.1±0.25
43.57±0.3
14.6±0.3
73.7
19.7
2.54±0.25
3.49±0.25
0.64 SQ
3.0 +1.0/-0.5
Description:
Powerex Intellimod™ Intelligent
Power Modules are isolated base
modules designed for power
switching applications operating
at frequencies to 20kHz. Built-in
control circuits provide optimum
gate drive and protection for the
IGBT and free-wheel diode
power devices.
Features:
□ Complete Output Power
Circuit
□ Gate Drive Circuit
□ Protection Logic
– Short Circuit
– Over Temperature
– Under Voltage
Applications:
□ Inverters
□ UPS
□ Motion/Servo Control
□ Power Supplies
Ordering Information:
Example: Select the complete
part number from the table below
-i.e. PM75RVA060 is a 600V,
75 Ampere Intellimod™ Intelligent
Power Module.
Type Current Rating
VCES
Amperes
Volts (x 10)
PM 75
60
375
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM75RVA060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
75 Amperes/600 Volts
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Characteristics
Power Device Junction Temperature
Storage Temperature
Case Operating Temperature
Mounting Torque, M5 Mounting Screws (Typical)
Mounting Torque, M5 Main Terminal Screws (Typical)
Module Weight (Typical)
Supply Voltage (Applied between P - N, Surge Value)
Supply Voltage Protected by SC (VD = 13.5 ~16.5V, Inverter Part, Tj = 125°C Start)
Isolation Voltage, AC 1 minute, 60Hz, Sinusoidal
Symbol
Tj
Tstg
TC
—
—
—
VCC(surge)
VCC(prot.)
VRMS
Control Sector
Supply Voltage Applied between (VUP1-VUPC, VVP1-VVPC, VWP1-VWPC, VN1-VNC)
Input Voltage Applied between (UP, VP, WP, UN, VN, WN, Br)
Fault Output Supply Voltage (Applied between FO-VNC, *FO-V*PC)
Fault Output Current (Sink Current at FO Terminals)
VD
VCIN
VFO
IFO
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, VCIN = 15V)
Collector Current, ± (TC = 25°C)
Peak Collector Current, ± (TC = 25°C)
Collector Dissipation (TC = 25°C)
VCES
IC
ICP
PC
Brake Sector
Collector-Emitter Voltage (VD = 15V, VCIN = 15V)
Collector Current, ± (TC = 25°C)
Peak Collector Current, ± (TC = 25°C)
Collector Dissipation (TC = 25°C)
FWDi Forward Current (TC = 25°C)
FWDi Rated DC Reverse Voltage (TC = 25°C)
VCES
IC
ICP
PC
IF
VR(DC)
PM75RVA060
-20 to 150
-40 to 125
-20 to 100
17
17
560
500
400
2500
20
20
20
20
600
75
150
284
600
30
60
178
30
600
Units
°C
°C
°C
in-lb
in-lb
Grams
Volts
Volts
Volts
Volts
Volts
Volts
mA
Volts
Amperes
Amperes
Watts
Volts
Amperes
Amperes
Watts
Amperes
Volts
376
|