Semikron International |
SKCD 61 C 060 I HD
CAL-DIODE
IF = 150 A
VRRM = 600 V
Size: 7,8 mm x 7,8 mm
SKCD 61 C 060 I HD
Features
• high current density
• easy paralleling due to a small forward
voltage spread
• positive temperature coefficient
• very soft recovery behavior
• small switching losses
• high ruggedness
• compatible to thick wire bonding
• compatible to standard solder
processes
Typical Applications*
• freewheeling diode for IGBT
Absolute Maximum Ratings
Symbol Conditions
Values
Unit
VRRM
IF(AV)
IFSM
Tjmax
Tj = 25 °C, IR = 0.3 mA
Ts = 80 °C, Tj = 175 °C
10 ms
Tj = 25 °C
sin 180°
Tj = 150 °C
Electrical Characteristics
Symbol Conditions
600
110
1300
1080
175
V
A
A
A
°C
min. typ. max. Unit
i2t
IR
VF
V(TO)
rT
Tj = 150 °C, 10 ms, sin 180°
Tj = 25 °C, VRRM = 600 V
Tj = 150 °C, VRRM = 600 V
Tj = 25 °C, IF = 160 A
Tj = 150 °C, IF = 160 A
Tj = 150 °C
Tj = 150 °C
5832 A2s
0.30 mA
mA
1.35 V
1.31 V
0.85 V
2.8 mΩ
Dynamic Characteristics
Symbol Conditions
min. typ. max. Unit
trr Tj = 25 °C, 150 A, 300 V, 1500 A/µs
µs
trr Tj = 150 °C, 150 A, 300 V, 1500 A/µs
ns
Qrr Tj = 25 °C, 150 A, 300 V, 1500 A/µs
µC
Qrr Tj = 150 °C, 150 A, 300 V, 1500 A/µs 22 µC
Irrm Tj = 25 °C, 150 A, 300 V, 1500 A/µs
A
Irrm Tj = 150 °C, 150 A, 300 V, 1500 A/µs
88
A
Thermal Characteristics
Symbol Conditions
min. typ. max. Unit
Tj
Tstg
Tsolder
Tsolder
Rth(j-s)
10 min.
5 min.
sold. on 0,38 mm DCB, reference point
on copper heatsink close to the chip
-40
-40
0.54
175 °C
175 °C
250 °C
320 °C
K/W
Mechanical Characteristics
Symbol Conditions
Raster
size
Area total
Anode
Cathode
Wire bond
Package
Chips /
Package
Values
7.8 x 7.8
60.84
bondable (Al)
solderable (Ag/Ni)
Al, diameter ≤ 500 µm
wafer frame
156 (5" Wafer)
Unit
mm2
mm2
pcs
SKCD
ww©w.bDyataSSEheMetI4KUR.nOet N
Rev. 0 – 18.02.2010
1
SKCD 61 C 060 I HD
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our personal.
2
Rev. 0 – 18.02.2010
© by SEMIKRON
|