Features
• Available in JAN, JANTX , JANTXV and JANS per MIL-PRF-19500/452
• 6.4 Volt Nominal Zener Voltage +5 %
• Metallurgically Bonded
Maximum Ratings
Operating & Storage Temperature: -65°C to +175°C
DC Power Dissipation: 500mW @ +50°C
Power Derating: 4 mW / °C above +50°C
REVERSE LEAKAGE CURRENT
lR = 2 μA @ 25°C & VR = 3 Vdc
Electrical Specifications @ +25 ºC (Unless Otherwise Specified)
JEDEC
Type
Number
1N4565UR, -1
1N4565AUR, -1
1N4566UR, -1
1N4566AUR, -1
1N4567UR, -1
1N4567AUR, -1
1N4568UR, -1
1N4568AUR, -1
1N4569UR, -1
1N4569AUR, -1
1N4570UR, -1
1N4570AUR, -1
1N4571UR, -1
1N4571AUR, -1
1N4572UR, -1
1N4572AUR, -1
1N4573UR, -1
1N4573AUR, -1
1N4574UR, -1
1N4574AUR, -1
1N4575UR, -1
1N4575AUR, -1
1N4576UR, -1
1N4576AUR, -1
1N4577UR, -1
1N4577AUR, -1
1N4578UR, -1
1N4578AUR, -1
1N4579UR, -1
1N4579AUR, -1
1N4580UR, -1
1N4580AUR, -1
1N4581UR, -1
1N4581AUR, -1
1N4582UR, -1
1N4582AUR, -1
1N4583UR, -1
1N4583AUR, -1
1N4584UR, -1
1N4584AUR, -1
Zener
Test
Current
mA
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
Effective
Temperature
Coefficient
%/°C
0.01
0.01
0.005
0.005
0.002
0.002
0.001
0.001
0.0005
0.0005
0.01
0.01
0.005
0.005
0.002
0.002
0.001
0.001
0.0005
0.0005
0.01
0.01
0.005
0.005
0.002
0.002
0.001
0.001
0.0005
0.0005
0.01
0.01
0.005
0.005
0.002
0.002
0.001
0.001
0.0005
0.0005
Voltage
Temperature
Stability
(3VZT maximum)
(Note1)
mV
48
100
24
50
10
20
5
10
2.5
5
48
100
24
50
10
20
5
10
2.5
5
48
100
24
50
10
20
5
10
2.5
5
48
100
24
50
10
20
5
10
2.5
5
Temperature
Range
°C
0 to +75
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to + 100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to + 75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
0 to +75°C
-55 to +100°C
Maximum Dynamic
Zener
Impeadance
(Note 2)
Ohms
200
200
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
100
100
50
50
50
50
50
50
50
50
50
50
25
25
25
25
25
25
25
25
25
25
NOTE 1: The maximum allowable change observed over the entire temperature range i.e., the diode voltage will not exceed the
specified mV at any discrete temperature between the established limits, per JEDEC standard No. 5.
NOTE 2: Zener impedance is derived by superimposing on lZT A 60Hz rms a.c. current equal to 10% of lZT.
Revision Date: 11/4/2009
New Product
1
Graphs
+.0015
+.0010
+.0005
0
-.0005
-.0010
-.0015
1N4565-1N4569
+.0010
+.0005
0
-.0005
-.0010
-.0015
.1 .2 .3 .4 .5 .6 .7 .8 .9
OPERATING CURRENT lZT (mA)
1N4575-1N4579
1N4565UR thru 1N4584AUR,
1N4565UR- thru 1N4584AUR-1
1N4570-1N4574
.25 .5
1.0 1.5 2.0
OPERATING CURRENT lZT (mA)
1N4580-1N4584
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
OPERATING CURRENT lZT (mA)
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
OPERATING CURRENT lZT (mA)
TYPICAL CHANGE OF TEMPERATURE COEFFICIENT WITH CHANGE IN OPERATING CURRENT
10000
10000
5000 1N4565-1N4574
5000 1N4575-1N4584
1000
500
1000
500
100 100
50 50
10
.25 .5 1.0 1.5 2.0 2.5 3.0 3.5
OPERATING CURRENT IZT (mA)
10
1.0 2.0 3.0 4.0 5.0 6.0
OPERATING CURRENT IZT (mA)
ZENER IMPEDANCE VS. OPERATING CURRENT
2 TEL: 603-641-SEMI (7364) • [email protected] • www.aeroflex.com/metelics
Revision Date: 2/2/2010
|