Yantel |
STCA0602N6
Smart Temperature Compensation Attenuator
DC~6GHz 50Ω 100mW 1~10dB N3~N9
Part No. Descriptions
TCA
** **
**
**
Series
Frequency Attenuation Temperature Coefficient Code Metallization Options
*
Termination Plating Options
TCA, STCA,
MTCA, HTCA,
(01 to 10)
or BTCA
(03, 06, 12 or 18) 1dB to 10 dB
(N3 to N10) or (P3 to P8)
Planar(no code), W1, W3, WB1 or G (no code)=lead free or (S)=Lead(Pb)
Part No.
Frequency
Range
(GHz)
Attenuation
(dB)
Temperature
Coefficient Code
Temperature
Coefficient
of Attenuation
(dB/dB/℃)
Max.
VSWR
(:1)
@1GHz@25℃
Max.
Input
Power
(mW)
Attenuation
Accuracy
(dB)
STCA0601N* DC-6
1
N3~N7
-0.003~ -0.007
1.20 100 ±0.5
STCA0602N* DC-6
2
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0603N* DC-6
3
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0604N* DC-6
4
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0605N* DC-6
5
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0606N* DC-6
6
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0607N* DC-6
7
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0608N* DC-6
8
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0609N* DC-6
9
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
STCA0610N* DC-6
10
N3~N9
-0.003~ -0.009
1.20 100 ±0.5
General Specifications
1.Frequency Range
DC to 6GHz
2.Attenuation
2dB
3.Attenuation Accuracy
at 25℃ ±0.5dB@1GHz
4.VSWR
1.20:1 Max. @1GHz at 25℃
1.20:1 typical @2GHz at 25℃
1.20:1 typical @3 GHz at 25℃
5.Nominal Impedance
50 Ohms
6.Power Rating
100 mW CW
7.Power Derating
100% @ 100℃
Derates to 0% @ 150℃
8.Operating Temperature
-55℃ to +150℃
9.Temperature Coefficient over Operating Temperature Range: See Table Above.
Temperature Coefficient Tolerance: ±0.001dB/dB/℃.
10.Substrate: Alumina (Al2O3)
11.Resistive material: Thick film
12.Terminal material: Thick film, Nickel barrier with pure tin plate (lead free) or with tin (Sn90) plate (10% lead contained)
13.Protective Coating: Thick film (ethyl acetate)
14.Package Outline: See Sheet 3.
15.Workmanship: per MIL-PRF-55342.
16.RoHS Compliant.
17.Electrostatic Discharge Control: per MIL-STD-1686.
Unit Marking dB Value (XX), Direction of Shift (N) and TCA Shift (X).
Legibility and Permanency: per MIL-STD-130.
Quality Assurance
1. Sample inspect per ANSI/ASQC Z1.4 general inspection, LEVEL II, AQL = 1.0.
1.1 Visual and mechanical examination for conformance to outline package requirements.
2. Select five (5) Units from lot measure attenuation from DC to 6GHz every 20°C over the temperature range -55°C to +125°C.
2.1 Calculate, using linear regression, the slope of the curve.
2.2 Calculate TCA using the following formula: TCA = Slope / Attenuation @ 25°C.
3. Test data required for customer.
Yantel Corporation
Add:2nd Floor,Building 2,Gaofa Technology Park,Longjing,Nanshan,Shenzhen,China.PC 518055
Tel:86-755-8355-1886 Fax:86-755-8355-2533
For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
1/3
STCA Response
STCA0602N6
Statistical Table of Attenuation(typ.) VS Temperature
ATT(dB)
Temp(℃)
3MHz
1GHz
2GHz
3GHz
-40 3.23 3.10 3.17 3.22
-35 3.13 3.02 3.10 3.14
-15 2.71 2.67 2.78 2.82
5 2.35 2.37 2.48 2.54
25 2.06 2.12 2.23 2.31
45 1.82 1.90 2.00 2.09
65 1.64 1.72 1.81 1.90
85 1.49 1.56 1.64 1.71
105 1.36 1.41 1.49 1.54
Typical VSWR @25℃
Power Rating & Derating Curve
Percent
of
Rated
Input
Power
100%
75%
50%
25%
0%
-55
25 100
Temperature (°C)
150
Yantel Corporation
Add:2nd Floor,Building 2,Gaofa Technology Park,Longjing,Nanshan,Shenzhen,China.PC 518055
Tel:86-755-8355-1886 Fax:86-755-8355-2533
For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
2/3
|