Advanced XTAL |
Specification AXIOM10
Oscillator type : OCXO in SMD package
Issue: 04 Date: 2005-07-15
Parameter
min. typ. max. Unit Condition
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature (steady state)
operating temperature range
vs. supply voltage variation
vs. load change
long term (aging) 1st year
@ +40°C, after 30 days
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Warm-up time
Phase noise
@12.8 MHz
www.DataSheet4U.com
Supply voltage VS
Current consumption
(steady state, @ +25°C)
Current consumption (warm-up)
Storage temperature range
10 120
10.0 / 12.8 / 19.44
± 500
± 200
± 100
± 50
-40 +80
-20 +70
-10 +60
± 10
± 10
± 200
MHz
MHz
ppm
ppb
ppb
ppb
ppb
°C
°C
°C
ppb
ppb
ppb
Note 2
@+25°C, VC= center
Option II = “200”
Option II = “100”
Option II = “50”
Option II = “200”
Option II = “100”
Option II = “50”
± 2 ppm
0.15 1.65 3.15 V
0.25 2.5
4.5 V
positive
100 kΩ
HCMOS
15
5
40 60
5
-95
-120
-140
-145
3.15 3.3
3.45
4.75 5.0
5.25
300
250
800
500
-45 +85
pF
ns
%
min
dBc
dBc
dBc
dBc
V
V
mA
mA
mA
mA
°C
Option I = “33”
Option I = “50”
@ VS/2
∆ffinal/f0 < ±0.1 ppm
10 Hz
100 Hz
1000 Hz
10000 Hz
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Enclosure (see drawing)
25.6x22.2x11.5 max. mm
IEC 61837 CO 28
Weight
9 gram
Packing
Bulk, Tape & reel
IEC 60286-3
ESD Sensitivity
1500
V HBM as in IEC 61000-
4-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Not all combinations of options available in the whole frequency range
Ordering Code:
Model (Specification)
AXIOM10
Option I Option II Frequency [MHz]
50 100 10.0
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM10
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing:
Pin connections
Pin # Symbol Function
1 VC Control Voltage (EFC)
2 VREF Reference Voltage
3 VS Supply Voltage
4 RF OUT RF Output
5 N.C. No Connection
6 N.C. No Connection
7 GND Ground
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
2-17
(if applicable)
Solderability
2-20
Resistance to
2-58
soldering heat
Shock*
2-27
IEC 60679-1
clause ...
4.3
4.6.2
4.6.3
4.6.8
www.DataShBeuemt4pU*.com
2-29 4.6.6
Free fall*
2-32 4.6.9
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
Damp heat, cyclic*
Cold
Climatic sequence*
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-14
2-2
2-30
2-1
1-7
2-3
4.6.5
4.6.14
4.6.15
4.6.16
4.6.17
4.6.18
4.7.1
4.7.2
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM10
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
|