Mitsubishi Electric Semiconductor |
MITSUBISHI INTELLIGENT POWER MODULES
PM75DSA120
FLAT-BASE TYPE
INSULATED PACKAGE
A
B
GGG
L
U
M T - DIA.
N SIDE P SIDE
1. VN1 1. VP1
(4 TYP.)
2. SNR 2. SPR
N
12 3 4 5
3. CN1 3. CP1
C2E1
E2
C1
4. VNC 4. VPC
C D 5. FNO 5. FPO
Q - DIA.
(2 TYP.)
R - M5 THD.
(3 TYP.)
12 3 4 5
P
P
S
S
S
S
0.64 MM SQ. PIN
H (10 TYP.)
EF
KJ
N
VP1
FPO
SPR
CP1
VPC
VN1
FNO
SNR
CN1
VNC
VCC
TEMP
FO
OUT1
SR OUT2
IN SENS
SINK
GND
VCC
TEMP
FO
OUT1
SR OUT2
IN SENS
SINK
GND
C1
C2E1
E2
Outline Drawing and Circuit Diagram
Dimensions Inches
Millimeters
A 4.33 110.0
B 3.66±0.010 93.0±0.25
C 1.77 45.0
D 1.34 34.0
E 1.14 +0.04/-0.02 29.0 +1/-0.5
F 1.02 26.0
G 0.98 25.0
H
0.702
17.84
J 0.55 14.0
K 0.51 13.0
Dimensions
L
M
N
P
Q
R
S
T
U
Inches
0.47
0.33
0.28
0.230
0.22 Dia.
M5 Metric
0.100
0.08 Dia.
0.08
Millimeters
12.0
8.5
7.0
5.84
Dia. 5.5
M5
2.54
Dia. 2.0
2.0
Description:
Mitsubishi Intelligent Power Mod-
ules are isolated base modules de-
signed for power switching applica-
tions operating at frequencies to
20kHz. Built-in control circuits pro-
vide optimum gate drive and pro-
tection for the IGBT and free-wheel
diode power devices.
Features:
ٗ Complete Output Power
Circuit
ٗ Gate Drive Circuit
ٗ Protection Logic
– Short Circuit
– Over Current
– Over Temperature
– Under Voltage
Applications:
ٗ Inverters
ٗ UPS
ٗ Motion/Servo Control
ٗ Power Supplies
Ordering Information:
Example: Select the complete
part number from the table below
-i.e. PM75DSA120 is a 1200V,
75 Ampere Intelligent Power Mod-
ule.
Type
PM
Current Rating
Amperes
75
VCES
Volts (x 10)
120
Sep.1998
MITSUBISHI INTELLIGENT POWER MODULES
PM75DSA120
FLAT-BASE TYPE
INSULATED PACKAGE
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings
Symbol
Power Device Junction Temperature
Storage Temperature
Case Operating Temperature
Tj
Tstg
TC
Mounting Torque, M5 Mounting Screws
—
Mounting Torque, M5 Main Terminal Screws
—
Module Weight (Typical)
—
Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V, Inverter Part)
Isolation Voltage (Main Termnal to Basepiate, AC 1 min.)
VCC(prot.)
Viso
Control Sector
Supply Voltage (Applied between VP1-VPC, VN1-VNC)
Input Voltage (Applied between CP1-VPC, CN1-VNC)
Fault Output Supply Voltage (Applied between Fpo-Vpc and Fno-Vnc)
Fault Output Current (Sink Current at FPO, FNO Terminal)
VD
VCIN
VFO
IFO
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, VCIN = 5V)
Collector Current, (Tc = 25°C)
Peak Collector Current, (Tc = 25°C)
Supply Voltage (Applied between C1 - E2)
Supply Voltage, Surge (Applied between C1 - E2)
Collector Dissipation
VCES
IC
ICP
VCC
VCC(surge)
PC
PM75DSA120
-20 to 150
-40 to 125
-20 to 100
2.5~3.5
2.5~3.5
340
800
2500
20
10
20
20
1200
75
150
900
1000
460
Units
°C
°C
°C
N·m
N·m
Grams
Volts
Vrms
Volts
Volts
Volts
mA
Volts
Amperes
Amperes
Volts
Volts
Watts
Sep.1998
|