Toshiba Semiconductor |
FIBER OPTIC RECEIVING MODULE
TORX176
FIBER OPTIC RECEIVING MODULE
FOR DIGITAL AUDIO EQUIPMENT
l Conform to JEITA Standard CP−1201 (For
Digital Audio Interfaces including Fiber
Optic inter−connections).
l TTL Interface
l ATC (Automatic Threshold Control)
Circuit is used for stabilized output at a wide
range of optical power level.
l A self−tapping hole for easy attachment to
the panel of Audio Equipment.
TORX176
Unit: mm
1. Maximum Ratings (Ta = 25°C)
Characteristics
Symbol
Rating
Storage Temperature
Operating Temperature
Supply Voltage
Low Level Output Current
High Level Output Current
Soldering Temperature
Tstg
Topr
VCC
IOL
IOH
Tsol
−40 to 70
−20 to 70
−0.5 to 7
20
−1
260 (Note 1)
Note 1: Soldering time ≤ 10 s (More than 1 mm apart from the package).
Unit
°C
°C
V
mA
mA
°C
2. Recommended Operating Conditions
Characteristics
Supply Voltage
High Level Output Current
Low Level Output Current
Symbol
VCC
IOH
IOL
Min Typ. Max Unit
4.75 5.0 5.25
V
― ― −150 µA
― ― 1.6 mA
1
2001-08-10
TORX176
3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V)
Characteristics
Symbol
Test Condition
Min Typ. Max Unit
Data Rate
Transmission Distance
Pulse Width Distortion
Maximum Receivable Power
Minimum Receivable Power
Rise Time
Fall Time
Current Consumption
High Level Output Voltage
Low Level Output Voltage
(Note 4)
(Note 5)
(Note 5)
∆tw
PMAX
PMIN
tr
tf
ICC
VOH
VOL
NRZ code
(Note 2)
TOTX176
Using APF
(Note 3)
Pulse width 165 ns
Pulse cycle 330 ns, CL = 10 pF
Using TOTX176
DC
0.2
−20
6 Mb/s, Using APF
−14.5
6 Mb / s, Using APF
CL = 10 pF
CL = 10 pF
―
―
―
―
2.7
―
―
―
―
―
―
10
5
22
―
―
6 Mb / s
10 m
20 ns
― dBm
−27 dBm
30 ns
30 ns
40 mA
―V
0.4 V
Note 2: For data rate > 3 Mb / s, the duty factor must be such as kept 25 to 75%. High level output when optical flux
is received. Low level output when optical flux is not received.
Note 3: All Plastic Fiber (970 / 1000 µm).
Note 4: Between input of a fiber optic transmitting module and output of TORX176.
Note 5: BER ≤ 10−9, rated by peak value.
2 2001-08-10
|