Power-One |
LHR, LGR 4/5000 Series
10...30 Watt AC-DC Converters
Input voltage ranges 85...265 V AC
88…168 V DC
1 or 2 outputs up to 48 V DC
4300 V DC I/O electric strength test voltage
LGA
• Class II equipment (double insulation)
• Short circuit protection
• Compact, low cost solution
Selection chart
Output 1
Uo nom Io nom
[V DC] [A]
3.3 3
3.3 7
52
55
12 1.2
12 2.5
15 1
15 2
24 0.6
24 1.25
3.3 1.5
3.3 2.5
+5 1.25
+5 2.5
+5 1
+5 2.5
+12 0.6
+12 1.25
+15 0.5
+15 1.0
+24 0.3
+24 0.625
Output 2
Uo nom Io nom
[V DC] [A]
--
--
--
--
--
--
--
--
--
--
+5 1
+5 2.5
-5 1.25
-5 2.5
+12 0.5
+12 1.25
-12 0.6
-12 1.25
-15 0.5
-15 1.0
-24 0.3
-24 0.625
Input voltage
Ui
85…264 V AC
(47…63 Hz)
88…168 V DC
Rated power
TA = 50°C
Po tot [W]
10
23
10
25
14.4
30
15
30
14.4
30
10
20.8
12.5
25
11
27.5
14.4
30
15
30
15
30
Type
LHR 4101-2
LGR 4101-2
LHR 4001-2
LGR 4001-2
LHR 4301-2
LGR 4301-2
LHR 4501-2
LGR 4501-2
LHR 4601-2
LGR 4601-2
LHR 5101-2
LGR 5101-2
LHR 5001-2
LGR 5001-2
LHR 5020-2
LGR 5020-2
LHR 5320-2
LGR 5320-2
LHR 5540-2
LGR 5540-2
LHR 5660-2
LGR 5660-2
www.power-one.com
Edition 5/07.2001
1
Board Mountable
LHR, LGR 4/5000 Series
Input
Input voltage
Input frequency
continuous range
85...264 V AC / 88…168 V DC
47...63 Hz
Output
Efficiency
Output voltage switching noise
Line and load regulation Uo1
Line and load regulation Uo2
Minimum load
Hold-up time
230 V AC, Io nom
Ui nom, Io nom, 20 MHz bandwidth, peak-peak
Ui min…Ui max, (10…100%) • Io nom
Ui min…Ui max, (10…100%) • Io nom
not required on single output types
recommended 0.1 Io nom on double output types
110/230 V AC, Io nom
up to 86%
<1 %
±1 %
±2 %
>10 ms
Protection
Output overload
Short circuit
No load
hiccup mode on LHR types / rectangular on LGR types
Control
Trim /R
±80…110% Uo nom
Safety and EMC
Safety marks
Electric strength test voltage
Electrostatic discharge
Electromagnetic field
Electr. fast transients/burst
Surge
Electromagnetic emissions
900 MHz Test
UL, ULc, CE
I/O
IEC/EN 61000-4-2, level 4 (15 kV)
IEC/EN 61000-4-3, level 3 (10 V/m)
IEC/EN 61000-4-4, level 3 (i, ±2 kV)
IEC/EN 61000-4-5, level 3 (2 kV)
CISPR 22/EN 55022, conducted
ENV50204, 3V/m
3000 V AC
criterion A
criterion A
criterion A
criterion A
class B
criterion A
Environmental
Ambient temperature
Storage temperature
Relative humidity
Shock
Random vibration
Ui nom, Io nom, convection cooled
non operational
non condensing
peak acceleration
–10...50 °C
–40...100 °C
5...95 %
20 gn
2 gn rms
Options
Trim pin not fitted
(single output units only)
www.power-one.com
Edition 5/07.2001
2
|