Microsemi |
2830 S. Fairview St.
Santa Ana, CA 92704
PH: (714) 979-8220
FAX: (714) 966-5256
MM054
Features
• High current capability, easy to parallel to further boost up performance
• Compact and rugged construction offering weight and space savings
• Available with PC board solderable pins (see mechanical outline below)
or threaded terminals (add “T”suffix to part number, see option below)
• HPM (Hermetic Power Module)
• Isolation voltage capability (in reference to the base) in excess of 3kV
• Very low thermal resistance
• Thermally matched construction provides excellent temperature and
power cycling capability
• Additional voltage ratings or terminations available upon request
• MIL-PRF-19500 screening available upon request
DISCHARGE: 100 A
CHARGE: 20 A
BATTERY
BYPASS
CIRCUIT
Maximum Ratings per leg @ 25°C (unless otherwise specified)
PART NUMBER
SYMBOL
MAX.
UNIT
Discharge Current
Charge Current
Non-Repetitive Peak Surge Current (discharge)
Non-Repetitive Peak Surge Current (charge)
Operating and Storage Junction Temperature Range
Thermal resistance, junction to base, discharge
Thermal resistance, junction to base , charge
ID
IC
IDSM
ICSM
Tj
Tstg
RΘ jbD
RΘ jbC
100
20
500
200
-55 to +175
0.7
(typ. 0.5)
0.9
(typ. 0.75)
Amps
Amps
Amps
Amps
°C
°C/W
°C/W
Mechanical Outline
Datasheet# MSC0322A
MM054
Electrical Parameters, DISCHARGE circuit @ 25°C (unless otherwise specified)
DESCRIPTION
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
SYMBOL
VD1
VD2
VD3
VD4
VD5
VD6
VD7
CONDITIONS
IF= 10 A,
IF= 20 A,
IF= 40 A,
IF= 80 A,
IF= 100 A,
IF= 20 A, TA= -55°C
IF= 20 A, TA= 125°C
MIN TYP. MAX UNIT
350 340 mV
400 470 mV
490 600 mV
530 800 mV
750 - mV
490 590 mV
320 - mV
note: see 1N6790 data sheet for full electrical characteristics of the discharge schottky
diode
Electrical Parameters, CHARGE circuit @ 25°C (unless otherwise specified)
DESCRIPTION
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
SYMBOL
VC1
VC2
VC3
VC4
VC5
VC4
CONDITIONS
IF= 50 mA
IF= 100 mA
IF= 5 A,
IF= 10 A,
IF= 20 A,
IF= 10 A, TA= 125°C
MIN TYP. MAX UNIT
2 2.1
-
V
- 2.2 -
V
2.6 2.7
V
2.7 3.0
V
2.85 3.3
V
2.35 2.7
V
Notes
(1) Pulse test, t ≤ 300 µs, duty cycle δ≤ 2%
|