MAX250/MAX251 Compatible Converter SM Transformers
FEATURES
n J-STD-020D reflow
n RoHS compliant
n Maxim MAX250/MAX251 compatible
n Isolation to 4kVrms
n Industry-standard pinout
n Surface mount option
n UL 94 V-0 package materials
n Low profile
n Toroidal construction
n Industrial temperature range
DESCRIPTION
The 78250 series of converter transformers
are specifically designed for use with Maxim
chipsets to provide isolated RS232 interfaces.
Carefully controlled turns ratios ensure consistent
performance whilst a toroidal construction
minimises EMI.
For through hole versions see 78250 datasheet.
For full details go to
www.murata-ps.com/rohs
CHARACTERISTICS 78250JC
Parameter
Primary Inductance, LP
Leakage Inductance, LL
Interwinding Capacitance, CWW
Primary D.C. Resistance, RDC
Volt-time Product, Et
Turns Ratio
Conditions
10kHz, 100mV
100kHz, 100mV
100kHz, 100mV
<0.1VDC
Pins1/2 or 2/3
Min. Typ. Max. Units
1.0 2.0 2.5 mH
0.6 3.0 μH
48 90 pF
0.7 2.0
50 Vμs
1:1
CHARACTERISTICS 78250JVC
Parameter
Primary Inductance, LP
Leakage Inductance, LL
Interwinding Capacitance, CWW
Primary D.C. Resistance, RDC
Volt-time Product, Et
Turns Ratio
Conditions
10kHz, 100mV
100kHz, 100mV
100kHz, 100mV
<0.1VDC
Pins1/2 or 2/3
Min. Typ. Max. Units
1.0 2.0 2.5 mH
35 40 μH
4 10 pF
0.9 1.8
50 Vμs
1:1
ORDER CODE DETAILS
Order Code
78250JC / 78250JVC
78250JC-R / 78250JVC-R
Package Type
6 Pin SM
6 Pin SM
Packaging Type
Tube
Tape & Reel
Quantity
50
500
ABSOLUTE MAXIMUM RATINGS
Operating free air temperature range
Storage temperature range
Lead temperature 1.5mm from case for 10 seconds
Peak current, IPK
Isolation voltage 78250(J)C (flash tested for 1 second)
Isolation voltage 78250V(J)C (flash tested for 1 second)
-40°C to 85°C
-50°C to 125°C
300°C
300mA
1.5kVrms
4.0kVrms
All specifications typical at TA=25°C
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’,
‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all
terms that relate to the same thing, a test voltage, applied for a
specified time, across a component designed to provide electri-
cal isolation, to verify the integrity of that isolation.
All products in this series are 100% production tested at
their stated isolation voltage.
A question commonly asked is, “What is the continuous volt-
age that can be applied across the part in normal operation?”
For a part holding no specific agency approvals both input
and output should normally be maintained within SELV limits
i.e. less than 42.4V peak, or 60VDC. The isolation test volt-
age represents a measure of immunity to transient voltages
and the part should never be used as an element of a safety
isolation system. The part could be expected to function cor-
rectly with several hundred volts offset applied continuously
across the isolation barrier; but then the circuitry on both
sides of the barrier must be regarded as operating at an
unsafe voltage and further isolation/insulation systems must
form a barrier between these circuits and any user-accessi-
ble circuitry according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation
testing of a barrier component can actually degrade
isolation capability, to a lesser or greater degree
depending on materials, construction and environ-
ment. This series has toroidal isolation transformers,
with no additional insulation between primary and
secondary windings of enameled wire. While parts
can be expected to withstand several times the stated
test voltage, the isolation capability does depend on
the wire insulation. Any material, including this enamel
(typically polyurethane) is susceptible to eventual
chemical degradation when subject to very high ap-
plied voltages thus implying that the number of tests
should be strictly limited. We therefore strongly advise
against repeated high voltage isolation testing, but if it
is absolutely required, that the voltage be reduced by
20% from specified test voltage.
This consideration equally applies to agency recog-
nized parts rated for better than functional isolation
where the wire enamel insulation is always supple-
mented by a further insulation system of physical
spacing or barriers.
www.murata-ps.com/support
KMP_78250JC_A03   Page 1 of 3


78250JVC 데이터시트, 핀배열, 회로
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
78250J Series
MAX250/MAX251 Compatible Converter SM Transformers
0.354
(9.0) Max.
0.5
(12.70)
0.375
(9.52) Max.
78250JC
XYYWW
1 Primary Secondary
2
3
6
5*
4
0.25
(6.35)
0.012 (0.30)
0.008 (0.20)
0.035 (0.90)
0.1 (2.54)
RECOMMENDED FOOTPRINT DETAILS
0.10 (2.54)
0.10 (2.54)
Ø0.05
(1.20)
+0.006
-0.000
(0.15)
(0.00)
0.04
(1.00)
0.45
(11.50)
0.025 (0.63)
0.021 (0.53)
Unless otherwise stated all dimensions in inches (mm) ±0.01 (0.25).
All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
* Pin 5 is connected to secondary center tap. Package Weight 1.0g TYP.
0.06 (1.60)
0.10 (2.54)
Unless otherwise stated all dimensions in inches (mm)
±0.01 (0.25). All pins on a 0.1 (2.54) pitch and within
±0.01 (0.25) of true position.
TUBE OUTLINE DIMENSIONS
0.43
(10.95)
0.16 (4.00)
0.023±0.005
(0.60±0.15)
0.22 (5.50)
0.15
(3.80)
0.62 (15.70)
0.51
(12.95)
Unless otherwise stated all
dimensions in inches (mm)
±0.01 (0.25).
Tube length: 18.3±0.08 (465±2).
Tube material: Antistatic coated
clear pvc.
SOLDERING INFORMATION1
Pin finish
Max. peak reflow temperature
Moisture sensitivity level2
Max. time above liquidous (217°C)
Matte tin
245°C
1
100s
1 For further information, please visit www.murata-ps.com/rohs
2 Representative samples of the product were subjected to the conditioning described in IPC/JEDEC
J-STD-020D and passed electrical testing, package coplanarity and visual inspection which
revealed no external cracks or changes in package body flatness.
www.murata-ps.com/support
KMP_78250JC_A03   Page 2 of 3




PDF 파일 내의 페이지 : 총 3 페이지

제조업체: Murata

( murata )

78250JVC transformer

데이터시트 다운로드
:

[ 78250JVC.PDF ]

[ 78250JVC 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


78250JVC

Transformers - Murata