파트넘버.co.kr CX-422 데이터시트 PDF


CX-422 반도체 회로 부품 판매점

Photoelectric Sensor



Sunx 로고
Sunx
CX-422 데이터시트, 핀배열, 회로
INSTRUCTION MANUAL
Photoelectric Sensor Amplifier Built-in
CX-400 Series
Thank you very much for using SUNX products.
Please read this Instruction Manual carefully and
thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient
place for quick reference.
٨ Never use this product as a sensing
device for personnel protection.
٨ In case of using sensing devices for personnel
protection, use products which meet standards,
WARNING such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
1 SPECIFICATIONS
Type
Thru-beam
Retroreflective
Long sens- With polarizing Long sens-
ing range filters (Note 2) ing range
Diffuse reflective
Narrow-view
Model No. NPN output
Item (Note 1) PNP output
Sensing range
CX-411
CX-411-P
10m
CX-412
CX-412-P
15m
CX-491
CX-491-P
3m
(Note 3)
CX-493
CX-493-P
5m
(Note 3)
CX-424
CX-424-P
100mm
(Note 4)
CX-421
CX-421-P
300mm
(Note 4)
CX-422
CX-422-P
800mm
(Note 4)
CX-423
CX-423-P
70 to 200mm
(Note 4)
Sensing object
Ǿ12mm or more opaque
object
Ǿ50mm or more Ǿ50mm or
opaque, translu- more opaque
cent or specular or translucent
object (Note 3) object (Note 3)
Opaque, translucent or transparent
object
Opaque,
translucent or
transparent
object (Note 5)
Repeatability
(perpendicular to sensing axis)
0.5mm or less
1mm or less
0.5mm or less
Supply voltage
12 to 24V DCr10% Ripple P-P 10% or less
Current consumption
Emitter: 20mA or less
(CX-412غ: 25mA or less)
Receiver: 20mA or less
20mA or less
25mA or less
20mA or less
Output
<NPN output type>
<PNP output type>
NPN open-collector transistor
PNP open-collector transistor
Maximum sink current: 100mA
Maximum source current: 100mA
Applied voltage: 30V DC or less (between output and 0V) Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1V or less (at 100mA sink current) Residual voltage: 1V or less (at 100mA source current)
0.4V or less (at 16mA sink current)
0.4V or less (at 16mA source current)
Output operation
Switchable either Light-ON or Dark-ON
Short-circuit protection
Incorporated
Response time
1ms or less
Operation indicator
Orange LED (lights up when the output is ON), thru-beam type sensor: located on the receiver
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition), thru-beam type sensor: located on the receiver
Power indicator
Green LED (lights up when the
power is ON), located on the emitter
Sensitivity adjuster
Automatic interference
prevention function
(Note 6)
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted closely.)
Protection
IP67 (IEC)
Ambient temperature
-25 to +55͠ (No dew condensation or icing allowed), Storage: -30 to +70͠
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Emitting element
Material
Cable
Red LED
(modulated)
Infrared LED
(modulated)
Red LED (modulated)
Infrared LED (modulated)
Enclosure: PBT, Lens: Acrylic, Indicator cover: Acrylic
0.2mm2 3-core (thru-beam type sensor emitter: 2-core) cabtyre cable, 2m long
Red LED
(modulated)
Weight
Emitter: 45g approx., Receiver: 50g approx.
50g approx.
Accessory
RF-230 (Reflector): 1 pc.
Notes: 1) The model No. with suffix '-J' is the M12 pigtailed type, '-Z' is the M8 connector type.
(e.g.) M12 pigtailed type: CX-411-J, M8 connector type: CX-411-Z
Use the connection cables as shown below. (Two sets are required for the thru-beam type sensor.)
<Connection cable for the M12 pigtailed type>
<Connection cable for the M8 connector type>
Type
Model No.
Cable length
Type
Model No.
Cable length
2-core type
CN-22-C2
CN-22-C5
2m
5m
Straight type
CN-24A-C2
CN-24A-C5
2m
5m
4-core type
CN-24-C2
CN-24-C5
2m
5m
Elbow type
CN-24AL-C2
CN-24AL-C5
2m
5m
The model No. with suffix 'E' shown on the label affixed to the thru-beam type sensor is the emitter, 'D' shown on the label is the receiver.
Thru-beam type sensor emitter: CX-41غE, Thru-beam type sensor receiver: CX-41غD
The model No. of retroreflective type sensor with the suffix '-Y' is the sensor without the RF-230 reflector.
(e.g.) CX-491-Y
Sensing range
2) The retroreflective type sensor with polarizing filters may not stably detect specular
(A)
or glossy objects through transparent film since light is polarized by the transparent
film. For details, refer to ' 8 RETROREFLECTIVE TYPE SENSOR WITH POLAR-
IZING FILTERS'.
Sensing
object
3) The sensing range and the sensing object of the retroreflective type sensor is specified
fot the RF-230 reflector. The sensing range represents the actual sensing range of the
sensor. The sensing ranges itemized in 'A' of the table below may vary depending of the
shape of sensing object. Be sure to check the operation with the actual sensing object.
Sensor
Reflector setting range
(B)
Reflector
4) The sensing range of the diffuse reflective type sensor is specified for white non-
CX-491غ
CX-493غ
glossy paper (200 ˜ 200mm) as the object.
A 3m
5m
5) The minimum sensing object of the diffuse reflectivenarrow-view type sensor is
Ǿ0.5mm copper wire.
B
0.1 to 3m
0.1 to 5m
6) By mounting interference prevention filters (PF-CX4-غ), two sets of the sensor can be mounted close together. For details, refer
to ' 10 INTERFERENCE PREVENTION FILTER (OPTIONAL)'.
2 CAUTIONS
٨ Make sure to carry out wiring in the power sup-
ply off condition.
٨ Take care that wrong wiring will damage the sensor.
٨ Verify that the supply voltage variation is within
the rating.
٨ If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.)
terminal of the power supply is connected to an
actual ground.
٨ In case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicini-
ty of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
٨ Do not run the wires together with high-voltage
lines or power lines or put them in the same race-
way. This can cause malfunction due to induction.
٨ Take care that the sensor is not directly exposed to fluo-
rescent lamp from a rapid-starter lamp or a high frequency
lighting device, as it may affect the sensing performance.
٨ Do not use during the initial transient time (50ms)
after the power supply is switched on.
٨ Extension up to total 100m, or less, is possible with
0.3mm2, or more, cable. However, in order to re-
duce noise, make the wiring as short as possible.
٨ Make sure that stress by forcible bend or pulling is
not applied directly to the sensor cable joint.
٨ This sensor is suitable for indoor use only.
٨ Do not use this sensor in places having excessive
vapor, dust, etc., or where it may come in direct
contact with water, or corrosive gas.
٨ Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
٨ When connecting the mating cable to the connector type
sensor, the tightening torque should be 0.4Nm or less.
3 MOUNTING
٨ The tightening torque should be 0.5Nm or less.
www.DataSheet4U.com
M3 (length 12mm)
screw with washers
Sensor mounting
bracket
(Optional)
4 I/O CIRCUIT DIAGRAMS
٨ NPN output type
Color code / Connector pin No. of
the connector type
D (Brown / 1) +V
(Black / 4)
Load
Output (Note)
+ 12 to 24V DC
Tr
ZD
100mA max.
- r10%
(Blue / 3) 0V
Internal circuit
Users' circuit
Note: The thru-beam type sensor emitter does not incorporate the
output.
Symbols...D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
٨ PNP output type
Color code / Connector pin No. of
the connector type
(Brown / 1) +V
ZD 100mA max.
Tr (Black / 4)
+ 12 to 24V DC
- r10%
Output (Note) Load
(Blue / 3) 0V
D
Internal circuit
Users' circuit
Note: The thru-beam type sensor emitter does not incorporate the
output.
Symbols...D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
٨ Connector pin position of the connector type
M12 pigtailed type
M8 connector type
2
Not con-
nected
3
0V
1
V
Output (Note)
2
Not con-
nected
1
V
Output (Note)
3
0V
Note: The thru-beam type sensor emitter does not incorporate the
output.
5 ADJUSTMENTS
٨ Part description
Stability indicator (Green)
(Note 1)
Lights up under the stable
light condition or the stable
dark condition
Operation indicator
(Orange) (Note 2)
Lights up when the
sensing output is
ON
Sensitivity adjuster
(Note 1)
Sensing range be-
comes longer when
turned clockwise
Operation mode switch
(Note 1)
L: Light-ON
D: Dark-ON
Notes: 1) Not incorporated on the thru-beam type sensor emitter.
2) It is the power indicator (green: lights up when the power
is ON) for the thru-beam type sensor emitter.
٨ Operation mode switch
Operation mode switch
Description
Light-ON mode is obtained when the opera-
tion mode switch (located on the receiver) is
turned fully clockwise (L side).
Dark-ON mode is obtained when the opera-
tion mode switch (located on the receiver) is
turned fully counterclockwise (D side).


CX-422 데이터시트, 핀배열, 회로
٨ Beam alignment
Thru-beam type sensor
Ԙ Set the operation mode switch to the Light-ON mode
position (L side).
Sensing object
ԙ Placing the emitter
and the receiver face
to face along a straight
line, move the emitter
in the up, down, left
and right directions, in
Emitter
order to determine the
range of the light re-
ceived condition with
Receiver
the help of the operation indicator (orange). Then, set
the emitter at the center of this range.
Ԛ Similarly, adjust for up, down, left and right angular
movement of the emitter.
ԛ Further, perform the angular adjustment for the re-
ceiver also.
Ԝ Check that the stability indicator (green) lights up.
ԝ Choose the operation mode, Light-ON or Dark-ON, as
per your requirement, with the operation mode switch.
Retroreflective type sensor
Ԙ Set the operation mode switch to the Light-ON mode
position (L side).
ԙ Placing the sensor
and the reflector
face to face along a
straight line, move
the reflector in the
up, down, left and
right directions, in
order to determine
the range of the
Sensor
Reflector
light received condition with the help of
the operation indicator (orange). Then, set the re-
flector at the center of this range.
Ԛ Similarly, adjust for up, down, left and right angular
movement of the reflector.
ԛ Further, perform the angular adjustment for the
sensor also.
Ԝ Check that the stability indicator (green) lights up.
ԝ Choose the operation mode, Light-ON or Dark-ON, as
per your requirement, with the operation mode switch.
٨ Sensitivity adjustment
Step Sensitivity adjuster
Description
Turn the sensitivity adjuster fully counter-
Ԙ clockwise to the minimum sensitivity posi-
tion, MIN.
In the light received condition, turn the sensitivity
ԙ adjuster slowly clockwise and confirm the point
where the sensor enters the 'Light' state operation.
In the dark condition, turn the sensitivity ad-
juster further clockwise until the sensor en-
ters the 'Light' state operation and then bring
Ԛ
it back to confirm point where the sensor
just returns to the 'Dark' state operation.
If the sensor does not enter the 'Light' state
operation even when the sensitivity adjuster is
turned fully clockwise, the position is point .
Optimum position
ԛ
The position at the middle of points
is the optimum sensing position.
and
Note: Use the 'minus' adjusting screwdriver (please arrange sepa-
rately) to turn the adjuster slowly. Turning with excessive
strength will cause damage to the adjuster.
Light received condition
Dark condition
Emitter
Receiver Emitter
Sensing
object
Receiver
Sensor
Reflector Sensor
Sensing
object
Reflector
Sensor
Sensing Sensor
object
6 AUTOMATIC INTERFERENCE
PREVENTION FUNCTION
(Excluding thru-beam type sensor)
٨ Retroreflective type sensor and diffuse reflective
type sensor incorporate this function. Up to two
sets of sensor can be mounted closely.
(Thru-beam type sensor does not have this function.)
Close mounting of two sensors
Note: If two diffuse reflective type sensor are mounted facing each
other, they should be angled so as not to receive the beam
from the opposing sensor or to detect its front face.
No good
ǰǰ
Good
7 LONG SENSING RANGE RET-
ROREFLECTIVE TYPE SENSOR
(CX-493š)
٨ Please take care of the following points when
detecting materials having a gloss.
Ԙ Make 'L', shown in the diagram, sufficiently
long.
ԙ Install at an angle of 10 to 30 degrees to the
sensing object.
L
Sensing
object
10 to 30q
Reflector
Glossy surface
* CX-491غ do not need the above adjustment.
8 RETROREFLECTIVE TYPE SEN-
SOR WITH POLARIZING FILTERS
(CX-491š)
٨ As light is polarized by a transparent film or mem-
brane, CX-491غ may not detect an object covered
or wrapped by transparent film. In that case, take
the following measures.
<Example of sensing objects>
Can wrapped by clear film
Aluminum sheet covered by plastic film
Gold or silver color (glossy) labels or wrapping
paper
<Measures>
Tilt the sensor with respect to the sensing object
upon fitting.
Reduce the sensitivity.
Increase the distance between the sensor and the
sensing object.
9 SLIT MASK (OPTIONAL)
(Exclusively for thru-beam type sensor)
٨ With the slit mask (OS-CX-غ), the sensor can
detect awswmawll.DobajetactS. heet4U.com
However, the sensing range is reduced when
the slit mask is mounted.
Type
Round slit mask
Rectangular slit
mask
Model No.
OS-CX-05
OS-CX-1
OS-CX-2
OS-CX-05g6
OS-CX-1g6
OS-CX-2g6
Slit size
Ǿ0.5mm
Ǿ1mm
Ǿ2mm
0.5˜6mm
1˜6mm
2˜6mm
How to mount
Ԙ Insert the fixing hook into the fixing groove.
ԙ Then, pressing the slit mask against the main
unit, insert the fixing tab into the fixing groove.
How to remove
Ԙ Insert a screwdriver into the removing tab.
ԙ Pull forward while lifting the removing tab.
Fixing groove
Fixing tab
Removing tab
Slit mask
Fixing groove
Fixing hook
10 INTERFERENCE PREVEN-
TION FILTER (OPTIONAL)
(Exclusively for CX-411š)
٨ By mounting the interference prevention filters
(PF-CX4-غ), two sets of the CX-411غ can be
mounted close together.
However, the sensing range is reduced when
the interference prevention filter is mounted.
٨ The filters can be mounted by the same method
as for the slit masks.
٨ Since there are two types of the interference
prevention filter, the two sets of sensors should
be fitted with different types of interference pre-
vention filters, as shown in the figure below.
The interference prevention does not work even
if the filters are mounted for emitters only, re-
ceivers only or the same model No. of the inter-
ference prevention filters are mounted on both
the sets of the sensor.
Fitted with
PF-CX4-H
Fitted with
PF-CX4-V
Relation between output and indicators : Lights up, : Turns off
In case of Light-ON
In case of Dark-ON
Stability Operation
indicator indicator
Output
ON
OFF
Sensing
condition
Stable light
receiving
Unstable light
receiving
Unstable dark
receiving
Stable dark
receiving
Output
OFF
ON
Operation Stability
indicator indicator
SUNX Limited http://www.sunx.co.jp/
Head Office
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
Overseas Sales Dept.
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
PRINTED IN JAPAN




PDF 파일 내의 페이지 : 총 2 페이지

제조업체: Sunx

( sunx )

CX-422 sensor

데이터시트 다운로드
:

[ CX-422.PDF ]

[ CX-422 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


CX-421

Photoelectric Sensor - Sunx



CX-421-P

Photoelectric Sensor - Sunx



CX-422

Photoelectric Sensor - Sunx



CX-422-P

Photoelectric Sensor - Sunx



CX-423

Photoelectric Sensor - Sunx



CX-423-P

Photoelectric Sensor - Sunx



CX-424

Photoelectric Sensor - Sunx



CX-424-P

Photoelectric Sensor - Sunx



CX-42x

COMPACT PHOTOELECTRIC SENSOR - Sunx