Terminal Relay
G6B-4jjND
Compact Terminal Relay with 4
Independent Outputs
Equipped with four G6B Mini-relays that are
compact, highly sensitive, and highly resistant to
dielectric surges, and that can switch 5 amps of
power.
Sealed plastic construction used for relays.
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate
maintenance (except for high-reliability models).
Standard models meet UL508 and CSA require-
ments.
DIN Track mounting, and screw mounting models
are available.
Ordering Information
Model Number Legend:
G6B-jjjjND
12 3
Note: UL508 and CSA requirements met by standard models.
1. Number of Poles
4: 4 poles (4PST-NO standard circuit)
47: 4 poles (4PST-NO long-life circuit)
48: 4 poles (4PST-NO high-reliability circuit)
RC
2. Mounting
None: DIN Track or screw mounting
3. Input Terminal
B: Philips screw (3.5 mm) terminals (4 independent points)
Classification
Contact form
Mounting method
Terminals
Rated voltage
Model
Equipped with
operation indicator and
diode to absorb coil
surge
4PST (standard)
DIN Track or screw Philips screw
mounting
terminal
5 VDC
12 VDC
24 VDC
G6B-4BND
4PST (long-life)
DIN Track or screw
mounting
4PST (high reliability)
Philips screw
terminal
5 VDC
12 VDC
24 VDC
G6B-47BND
G6B-48BND
Note: 1. For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal when it was pur-
chased. Longer operating life can be achieved by replacing the G6B-4jjND with the G6B-1147P-FD-US.
2. Standard models are also available without relays mounted to the sockets. To obtain such terminals, replace the “G6B” portion of
the model number with “P6BF.” For example, to order G6B-4BND with empty sockets, use model number P6BF-4BND. Also specify
voltage specifications for models with operation indicators.
Accessories (Order Separately)
Replacement Relays
Applicable terminal relay
Rated voltage
G6B-4BND
5 VDC
12 VDC
24 VDC
G6B-47BND
5 VDC
12 VDC
24 VDC
Note: Relays cannot be replaced for G6B-48BND, which is mounted directly to boards.
Model
G6B-1114P-FD-US
G6B-1174P-FD-US
1

1 page




G6B-4BND pdf
G6B-4jjND
Precautions
Refer to page NO TAG for general precautions.
Wiring
Be sure to turn OFF the power when wiring the Unit and do not touch
the charged terminals of the Unit. Otherwise, an electric shock may
result.
Do not apply overvoltage to the input terminals. Otherwise, the Unit
may malfunction or burn.
Relay Models
Do not connect the Unit to loads exceeding the rated switching pow-
er (switching voltage or current). Otherwise, faulty insulation, con-
tact weld, or faulty contact of Relays, or damage to Relays may re-
sult, or the Relays may malfunction or burn.
The life of Relays varies with the switching condition. Test the
Relays under the actual operating conditions before using the
Relays within the permissible switching frequency. The use of dete-
riorated Relays may result in the faulty insulation of the Relays or
cause the Relays to burn.
Do not use the Unit in locations with inflammable gas. Otherwise, a
fire or explosion due to the heat of the Relays or sparks from the
Relays may result when they are switched.
Correct Use
Mounting
Heat generated by the relays must be considered when gang-
mounting. Space must be provided between the relays or other
methods must be taken to maintain the relays’ ambient temperature
at 55 _C or lower.
Replacement of Relays
G6B-4jjND
Use the P6B-Y1 Removal Tool as shown in the following diagram.
G6B-4jjND
Do Not Use the Following Circuit
Inductive load
G6B Coil
Coil surge current
absorption diode
Handling
Do not drop, shock, or vibrate the Unit excessively. Otherwise, dam-
age to the Unit may result or the Unit may malfunction.
Make sure that all the Relays are properly mounted before use.
Screw Tightening Torque
Tighten each terminal screw to a torque of 0.78 to 1.18N S m.
Tighten each mounting screw to a torque of 0.59 to 0.98 N S m.
Installation Environment
Do not install the Unit in the following locations. Otherwise, damage
to the Unit may result or the Unit may malfunction.
Locations with direct sunlight.
Locations with an ambient temperature range not within 0#C to
55#C.
Locations with rapid temperature changes resulting in condensa-
tion or locations with relative humidity ranges not within 10% to
90%.
Locations with corrosive or inflammable gas.
Locations with excessive dust, salinity, or metal powder.
Locations with vibration or shock affecting the Unit.
Locations with water, oil, or chemical sprayed on the Unit.
Disassembly, Repair, and Modification
Do not disassemble, repair, or modify the Unit. Otherwise, an elec-
tric shock may result or the Unit may malfunction.
Be sure to turn OFF the power to the Unit before replacing a Relay.
Relays must be inserted straight onto the socket connector pins to
ensure proper connection.
G6B-48BND models (high reliability) are connected directly to
boards to increase reliability and the relays are thus not replace-
able. If relay replacement is necessary, use the P6BF-4BND Termi-
nal Sockets together with the G6B-1184P Mini Relays. P6BF-4BND
Terminal Sockets are equipped with relay replacement sockets.
Do not mount Relays that are different to one another in voltage.
Relays Mounted
G6B-4jjND standard:
G6B-1114P-FD-US
G6B-4jjND long life:
G6B-1174P-FD
G6B-4jjND high reliability: G6B-1184P-US
Replacement is not possible for G6B-48BND.
Wiring
Be sure to connect the input terminals with the correct polarity.
Coil Voltage
Be sure not to impose voltage exceeding the permissible voltage on
the coil continuously.
Do not use the relays when other inductive loads are connected in
parallel with the coil input or when there are surges during power
supply because the built-in diodes used to absorb surge may be de-
stroyed.
5

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet G6B-4BND.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
G6B-4BNDTerminal RelayOmron Electronics
Omron Electronics

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar