Solid State Relays
G3PA
Extremely Thin Relays Integrated with Heat Sinks
• Downsizing achieved through optimum design of heat sink.
• Mounting possible via screws or via DIN track.
• Close mounting possible for linking terminals. (Except for
G3PA-260B-VD and G3PA-450B-VD-2.)
• Applicable with 3-phase loads.
• Replaceable power element cartridges.
• Complies with VDE 0160 (finger protection), with a dielec-
tric strength of 4,000 V between input and load.
• Complies with VDE 0805, IEC 950.
• Certified by UL, CSA, and VDE (reinforced insulation).
Ordering Information
List of Models
To Order: Select the part number and add the rated input voltage range. (e.g., G3PA-430B-VD-2 DC12-24)
Isolation
Phototriac
coupler
Zero cross function
Yes
No
Yes
Indicator
Yes
Rated output load
10 A at 24 to 240 VAC
20 A at 24 to 240 VAC
40 A at 24 to 240 VAC
60 A at 24 to 240 VAC
10 A at 24 to 240 VAC
20 A at 24 to 240 VAC
40 A at 24 to 240 VAC
60 A at 24 to 240 VAC
10 A at 24 to 240 VAC
20 A at 24 to 240 VAC
40 A at 24 to 240 VAC
60 A at 24 to 240 VAC
20 A at 180 to 400 VAC
30 A at 180 to 400 VAC
20 A at 200 to 480 VAC
30 A at 200 to 480 VAC
50 A at 200 to 480 VAC
Rated input voltage
5 to 24 VDC
24 VAC
12 to 24 VDC
Model
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-210BL-VD
G3PA-220BL-VD
G3PA-240BL-VD
G3PA-260BL-VD
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-420B-VD
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
Solid State Relays G3PA
437
http://www.Datasheet4U.com

1 page




G3PA pdf
Replacement Procedure
G32A-A10(L)-VD/G32A-A20(L)-VD/G32-A420-VD(-2)
Use the special tool (provided) to extract the cartridge for replacement with a new one.
Extraction
Follow the procedures belo w to re move the Power Device Car tridge
from the G3PA.
1. Switch off the power.
2. Remove the terminal cover.
3. Hook the indented part of the cartridge with the tool (supplied with
a new cartridge) and pull up on the cartridge to remove it.
Remover
Hook here with
Remover.
Apply silicone grease here.
2. Make sure that there is no dust or pieces of wire on the heat sink
of the G32A-A or the G3PA.
3. Insert the car tridge into the opening of the G3P A so that the let-
ters on the car tridge and those on the G3PA are in the same
direction and side A and side B are even.
Side A
Side B
Installation
Follow the procedures below to Install the Power Device Cartridge on
the G3PA.
1. Apply silicone g rease (pro vided with the G32A-A) to the entire
surface of the heat sink.
4. Attach the terminal cover.
5. Switch on the po wer an d chec k the G3P A to be su re it w orks
properly.
G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2
The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit.
Extraction
Follow the procedures belo w to remo ve the G32A-A P ower Device
Cartridge from the G3PA.
1. Switch off the power.
2. Remove the terminal cover.
3. Loosen the two centered screws on the sides to dismount the car-
tridge. The screws are connected to terminals 1 and 2.
Installation
Follow the procedures below to Install the Power Device Cartridge on
the G3PA.
1. Apply silicone grease to the entire surface of the heat sink.
Loosen
Loosen
4. Loosen the screws on both the corners.
Apply silicone grease here.
2. Make sure that there is no dust or pieces of wire on the heat sink
of the G32A-A or the G3PA.
Loosen
Loosen
5. Hold the indented part of both the corners to remove
the cartridge.
Solid State Relays G3PA 441

5 Page





G3PA arduino
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3PA-210B(L)-VD
Without Terminal
Cover
Two, M4
Linking terminal B1
With Terminal
Cover
4.6 dia.
Linking
terminal B2
Two,
M3.5
4.6 x 5.6 elliptical
hole
100 max.
G3PA-220B(L)-VD
Without Terminal
Cover
Two, M 4
Linking terminal B1
With Terminal
Cover
4.6 dia.
Linking terminal B2
Two,
M3.5
4.6 x 5.6 elliptical
hole
100 max.
G3PA-240B(L)-VD
Without Terminal
Cover
Linking
Two, M5
terminal B1
With Terminal
Cover
4.6 dia.
Linking
terminal B2
Two,
M3.5
4.6 x 5.6 elliptical
hole
100 max.
Mounting
Holes
Terminal
Arrangement/
Internal Connections
Two, 4.5 dia. or M4 holes
Mounting
Holes
Terminal
Arrangement/
Internal Connections
Two, 4.5 dia. or M4 holes
Mounting
Terminal
Holes
Arrangement/
Internal Connections
Two, 4.5 dia. or M4 holes
Solid State Relays G3PA 447

11 Page







PáginasTotal 18 Páginas
PDF Descargar[ Datasheet G3PA.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
G3PAExtremely Thin Relays IntegratedOMRON
OMRON
G3PA-VDExtremely Thin Relays IntegratedOMRON
OMRON
G3PCSSROmron
Omron
G3PC-220B-VDSSROmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar