Fujitsu |
MINIATURE RELAY
2 POLES—1 to 2 A (FOR SIGNAL SWITCHING)
RY SERIES
s FEATURES
q Ultra high sensitivity
q UL, CSA recognized
q Conforms to FCC rules and regulations Part 68
—Surge strength 1,500 V
q High dielectric strength type available (RY-WF type)
q Contact arrangement MBB type available (RY-D type)
q High reliability-bifurcated contacts
q Wide operating range
q DIL pitch terminals
q Plastic sealed type
s ORDERING INFORMATION
[Example]
RY – 12 WF – K
(a) ( * ) (b) (c) (d)
(a) Series Name
RY : RY Series
(b) Nominal Voltage
Refer to the COIL DATA CHART
(c) Coil and Contact Function
W : High sensitive type
WZ : Nominal 0.5 W type
WF : High dielectric strength type
WFZ : 2 A type
D : 2 FORM D (2 MBB type)
(d) Enclosure
K : Plastic sealed type
Note: Actual marking omits the hyphen (-) of (*)
For movable and stationary contact with gold overlay type, add suffix “–OH”.
1
http://www.Datasheet4U.com
s SAFETY STANDARD AND FILE NUMBERS
UL478, 508 (FIle No. E45026)
C22.2 No. 14 (File No. LR35579)
Please request when the approval markings are required on the cover.
Please note that UL/CSA ratings may differ from the standard ratings.
Type
Nominal voltage
Contact rating*1
RY-W
RY-WZ
3 to 48 VDC
0.5 A
1A
0.3 A
120 VAC
24 VDC
60 VDC
resistive
RY-WF
5 to 48 VDC
0.25 A
1A
0.3 A
120 VAC
48 VDC
60 VDC
resistive
RY-WFZ
3 to 48 VDC
0.5 A
2A
0.6 A
120 VAC
30 VDC
110 VDC
resistive
RY-D
4.5 to 48 VDC
0.3 A 120 VAC
0.2 A 60 VDC
resistive
Note: *1 Contact ratings mentioned above are subject to same polarity.
RY SERIES
2