Omron Corporation |
Low Signal Relay
G6A
• High sensitivity -- can be driven by digital circuits.
• Low-profile design allows use in 12.70 mm (0.50 in) PC board
rack.
• Surge withstand voltage meets FCC Part 68 regulation.
• Units can be mounted side by side due to low magnetic
leakage.
• Special models available for ultrasonic cleaning and low
thermoelectromotive force.
www.DataS•hUeenti4qUu.ecommoving loop (permanent magnet) armature reduces
relay size, magnetic interference, and contact bounce time.
• Single or dual coil winding types available.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).
I Non-latching
Type
Standard
High-sensitivity
Low-sensitivity
Contact form
DPDT
4PDT
DPDT
4PDT
DPDT
4PDT
AgPd (Au clad)
G6A-234P-ST-US
G6A-434P-ST-US
G6A-234P-ST15-US
G6A-434P-ST20-US
G6A-234P-ST40-US
G6A-434P-ST40-US
Model
Ag (Au clad)
G6A-274P-ST-US
G6A-474P-ST-US
G6A-274P-ST15-US
G6A-474P-ST20-US
G6A-274P-ST40-US
G6A-474P-ST40-US
I Latching
Single Coil
Type
Standard
Contact form
DPDT
4PDT
AgPd (Au clad)
G6AU-234P-ST-US
G6AU-434P-ST-US
Model
Ag (Au clad)
G6AU-274P-ST-US
G6AU-474P-ST-US
Dual Coil
Type
Standard
Low-sensitivity
Contact form
DPDT
4PDT
DPDT
4PDT
AgPd (Au clad)
G6AK-234P-ST-US
G6AK-434P-ST-US
G6AK-234P-ST40-US
G6AK-434P-ST40-US
Model
Ag (Au clad)
G6AK-274P-ST-US
G6AK-474P-ST-US
G6AK-274P-ST40-US
G6AK-474P-ST40-US
Note: Other options available for ST10 ultra high reliability, high temperature 85°C (185°F), ST1 reverse coil polarity, BS British standard. Contact
your OMRON sales representative for details.
528 Low Signal Relay G6A
Specifications
I Contact Data
Type
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
www.DataSheet4UM.acxo.mswitching capacity
Min. permissible load
G6A-234P-ST(15,40)-US, G6A-434P-ST(20,40)-US
G6AK-234P-ST(40)-US, G6AK-434P-ST(40)-US
G6AU-234P-ST-US, G6AU-434P-ST-US
G6A-274P-ST(15,40)-US, G6A-474P-ST(20,40)-US
G6AK-274P-ST(40)-US, G6AK-474P-ST(40)-US
G6AU-274P-ST-US, G6AU-474P-ST-US
Resistive load (p.f. = 1) Inductive load (p.f. = 0.4) Resistive load (p.f. = 1) Inductive load (p.f. = 0.4)
(L/R = 7 ms)
(L/R = 7 ms)
0.30 A at 125 VAC,
1 A at 30 VDC
0.20 A at 125 VAC,
0.50 A at 30 VDC
0.50 A at 125 VAC,
2 A at 30 VDC
0.25 A at 125 VAC,
1 A at 30 VDC
AgPd (Au clad)
AgPd (Au clad)
Ag (Au clad)
Ag (Au clad)
3A 3A 3A 3A
250 VAC, 220 VDC
250 VAC, 220 VDC
250 VAC, 220 VDC
250 VAC, 220 VDC
2A 1A 2A 1A
125 VA, 60 W
62.50 VA, 30 W
125 VA, 60 W
62.50 VA, 30 W
10 µA, 10 mVDC
10 µA, 10 mVDC
10 µA, 10 mVDC
10 µA, 10 mVDC
I Coil Data
Standard Non-latching DPDT (G6A-234P-ST-US, G6A-274P-ST-US)
Rated
voltage
(VDC)
3
5
6
9
12
24
48
Rated
current
(mA)
66.70
40
33.30
22.20
16.70
8.30
4.90
Coil
resistance
(Ω)
45
125
180
405
720
2,880
9,750
Coil inductance
(ref. value) (H)
Armature
OFF
0.07
0.20
0.29
0.63
1.10
4.50
13.70
Armature
ON
0.07
0.18
0.26
0.57
1.06
4.10
12.50
Pick-up
voltage
Dropout
voltage
Maximum
voltage
% of rated voltage
70% max.
10% min.
200%
at 23°C
(73°F)
150%
at 70°C
(158°F)
Power
consumption
(mW)
Approx. 200
Approx. 235
High-sensitivity Non-latching DPDT (G6A-234P-ST15-US, G6A-274P-ST15-US)
Rated
voltage
(VDC)
1.50
3
4.50
5
6
9
12
24
48
Rated
current
(mA)
100
50
33.30
30
25
16.70
12.50
6.30
3.20
Coil
resistance
(Ω)
15
60
135
167
240
540
960
3,840
15,000
Coil inductance
(ref. value) (H)
Armature
OFF
Armature
ON
0.02
0.02
0.09
0.08
0.22
0.20
0.25
0.21
0.35
0.31
0.80
0.70
1.35
1.25
5.60
5.10
22.50
20.00
Pick-up
voltage
Dropout
voltage
Maximum
voltage
% of rated voltage
80% max.
10% min.
200%
Power
consumption
(mW)
Approx. 150
Note: The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
Low Signal Relay G6A
529
|