(VF4 Series) 40 Amp Relay



Siemens 로고
Siemens
VF4-xxxx 데이터시트, 핀배열, 회로
VF4 series
40 Amp Relay
With PC Board or
Quick Connect Terminals
for Automotive Applications
Features
• 40A continuous contact rating @ 85°C.
• 1 Form A and 1 Form C arrangements.
• Plug-in or PC board terminals.
• Optional mounting bracket.
• Various enclosure options.
Conditions
All parametric, environmental and life tests are performed according to EIA
Standard RS-407-A at standard test conditions (23°C Ambient, 20-50% RH,
29.5 ± 1.0" Hg.) unless otherwise noted.
Contact Data
Arrangements: 1 Form A (SPST-NO) and 1 Form C (SPDT).
Material: AgNi 0.15 (consult factory for other contact materials).
Max. Switching Rate: 20 operations per second with no contact load.
6 operations per minute for rated life at rated load.
Max. Switching Voltage: 75VDC(1).
Max. Load Current (@ 14VDC Load Voltage):
www.DataSheet4U.com
Load
Max. Continuous Current
Max. Make Current (2)
Max. Break Current (1)
Form A
(NO)
60A
120A
60A
NO
60A
120A
60A
Form C
NC
40A
45A
40A
Max. Switching Power: 50-500 watts DC (voltage dependent) (1).
Min. Recommended Current: 1 amp @ 12VDC.
Initial Voltage Drop: 200 millivolts, maximum, for normally open contacts
@ 40 amp contact load.
250 millivolts, maximum, for normally closed
contacts @ 30 amp contact load.
Expected Life: 10 million operations, mechanical; 100,000 operations at 40
amps, 14VDC, resistive load on normally open contact.
Initial Dielectric Strength
Between Contacts and Coil: 500V rms.
Coil Data
Voltage: 6, 12 and 24VDC.
Resistance: See Coil Data table.
Nom. Power: (@ 23°C coil temp. and rated coil voltage.):
1.6W, unsuppressed.
1.81W, with 680 ohm resistor.
Thermal Resistance: 50°C per actual coil watt in still air with no contact
load current.
Coil Data
Coil
Designator
Rated Coil
Voltage
(VDC)
Coil
Resistance
±10% (Ohms)
Coil
Inductance
(H) (Ref.)
D 6 22.5 0.2
F 12 90
0.8
H 24 360
2.7
Operate Data
Must Operate and Must Release Voltage: See Coil Data table.
Initial Operate Time: 7 milliseconds, typical, with rated coil voltage
applied.
Initial Release Time: 2 milliseconds, typical, with zero volts applied (for
unsuppressed relays after having been energized at
rated coil voltage.)
Environmental Data
Temperature Range: Storage: -40°C to +155°C.
Operating: -40°C to +125°C (4).
Shock: 20g, 11 milliseconds, half sine wave pulse.
Vibration: (For NC contacts, NO contacts are significantly higher.)
10-40 Hz., 1.27mm double amplitude.
40-70 Hz., 5 g's constant.
70-100 Hz., 0.5mm double amplitude.
100-500 Hz., 10 g's constant.
Mechanical Data
Termination: 0.250" quick connect and printed circuit terminals.
Enclosures:
Dust Cover: Protects relay from dust. For use in passenger
compartment or enclosures.
Shrouded Dust Cover: Protects relay and relay connector (order
separately) from dust and splash.
Weatherproof Cover: Mates with a connector (order separately) to seal
relay from salt spray etc. Recommended for under
hood application.
Cover Retention: Dust cover will withstand a 33.7 pound (150 Newton)
force (axially applied) without detachment. Ultrasonic
cover: 50 pound (220 Newton).
Weight: 31g (1.1 oz.) approximately (dust cover model).
Abnormal Operation
Overload Current: Consult factory.
24V Jump Start: 24VDC for 5 minutes conducting rated contact current
@ 23°C.
Drop Test: Capable of meeting specifications after a 3.28 foot (1.0 meter)
drop onto concrete.
Flammability: UL94V-0 external; UL94-HB or better, internal parts (meets
FMVSS 302).
Notes
(1) See Figure 1.
(2) Inrush current for lamp load.
(3) Allowable overdrive is rated at ambient temperature for 23°C or 85°C as
stated with no load current flowing through the relay contacts and
minimum coil resistance. Also see Figure 2 for maximum ambient
temperature versus applied coil voltage.
(4) See Figure 2.
(5) Current and times are compatible with circuit protection by a typical
automotive circuit breaker. Relay will make, carry and break the
specified current.
Must-Operate
Voltage
(VDC)
3.6
7.2
14.4
Must-Release
Voltage
(VDC)
0.6
1.2
2.4
Allowable (3)
Overdrive
(VDC)
@ 23°C
@ 85°C
10.1
20.2
40.5
7.9
15.7
31.5


VF4-xxxx 데이터시트, 핀배열, 회로
Figure 1 – Limiting Curve for Power Load
75
60
50
40
30
20
10
0.5
1
500W
100W 200W
2 3 4 5 7 10
Switching Current (Amps)
20 30 40
Safe breaking, arc extinguished (normally open contact) for resistive loads.
Figure 2 – Ambient Temperature vs. Coil Voltage for Continuous Duty
130
120
110
100
90
80
70
60
50
www.DataSheet4U.co4m0
30
90
0 Amp Contact Load
8 Amp Contact Load
16 Amp Contact Load
24 Amp Contact Load
Assumptions:
1. Thermal resistance = 50°C per watt
2. Still air
3. Nominal coil resistance
4. Maximum mean coil temperature = 180°C
5. Coil temperature rise due to load
= 2°C @ 8 amps
= 5°C @ 16 amps
= 11°C @ 24 amps
= 20°C @ 32 amps
= 32°C @ 40 amps
6. Thermal resistance and power dissipation
based on coil resistance at 180°C
7. Curves are based on 1.6 watts at 23°C
8. When full lifetime is at high ambient and high
load current, subtract 25°C from maximum
allowable ambient temperature.
32 Amp Contact Load
40 Amp Contact Load
95 100 105 110 115 120 125 130 135 140 145 150
Applied Coil Voltage (% of Rated Nominal)
Ordering Information
Part Number
VF4-11 * 11
VF4-11 * 13
VF4-15 * 11
VF4-15 * 13
VF4-25 * 11
VF435 * 11
VF4-41 * 11
VF4-45 * 11
VF4-45 * 21
VF4-51 * 11
VF4-55 * 11
VF4-61 * 11
VF4-65 * 11
VF4-81 * 11
VF4-85 * 11
Contact
Arrangement
1 Form A
1 Form A
1 Form C
1 Form C
1 Form C
1 Form C
1 Form A
1 Form C
1 Form C
1 Form A
1 Form C
1 Form A
1 Form C
1 Form A
1 Form C
Contact
Material
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgSnO
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
Enclosure
Dust cover
Dust cover
Dust cover
Dust cover
Shrouded dust cover
Weatherproof cover
Dust cover with bracket
Dust cover with bracket
Dust cover with bracket
Shrouded dust cover with bracket
Shrouded dust cover with bracket
Weatherproof cover with bracket
Weatherproof cover with bracket
Dust cover with molded bracket
Dust cover with molded bracket
Terminals
Quick connect
Printed circuit
Quick connect
Printed circuit
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
Quick connect
*Standard Coil Voltages:
D = 6VDC (Consult factory for availability).
F = 12VDC
H = 24VDC (Consult factory for availability).
Optional Coil Suppression
Add suffix -S07 for 180 ohm resistor in parallel with 6VDC coil.
Add suffix -S01 for 680 ohm resistor in parallel with 12VDC coil.
Add suffix -S08 for 2,700 ohm resistor in parallel with 24VDC coil.
Epoxy Sealed Construction
Add suffix -C01 for epoxy sealed unit.
Stock Items – The following items are normally maintained in stock for immediate delivery.
VF4-11F11
VF4-11F13
VF4-15F11
VF4-15F11-S01
VF4-15F13
VF4-15F13-C01
VF4-15H11
VF4-15H13
VF4-41F11
VF4-45F11




PDF 파일 내의 페이지 : 총 4 페이지

제조업체: Siemens

( siemens )

VF4-xxxx relay

데이터시트 다운로드
:

[ VF4-xxxx.PDF ]

[ VF4-xxxx 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


VF4-xxxx

(VF4 Series) 40 Amp Relay - Siemens