(R10-Series) General Purpose Dry Circuit AC / DC Relay



Tyco 로고
Tyco
R10-Exxx-xxxx 데이터시트, 핀배열, 회로
www.DataSheet4U.com
Catalog 1308242
Issued 3-03
P&B
R10 series
General Purpose
Dry Circuit to 7.5 Amp
Multicontact AC or DC Relay
• R10-E – Clear Dust Cover Version
• R10-R – Sealed, Immersion Cleanable Type
• R10S – Super Sensitive, Logic Compatible
R10
R10-R
R10S
File E29244
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Broad range of coil options provide sensitivity ranging from 25 to 750mW.
• Various contacts switch from dry circuit to 7.5 amps.
• Many mounting and termination options.
Contact Data @ 25°C
Arrangements: 1 Form C (SPDT) through 8 Form C (8PDT) See Ordering
Information tables for more details regarding availability.
Contact Materials, Styles & Ratings @ +25°C
Contact
Code
Contact
Material
Contact
Style
Coil Codes Contact Ratings
Available Min. Typ. Max.
W Silver-Cadmium Oxide Single Button
V, Q, S, J 500mA
- 7.5A‡
X Silver-Cadmium Oxide Single Button V, Q, S, J 500mA - 5A§
Y
Fine Silver
Single Button
All 100mA 2A 3A
Z
Fine Silver
Bifurcated
All 1mA 100mA 2A
P Gold overlay on Silver Bifurcated Crossbar All Dry Circuit 1mA 3A
Ratings are at 28VDC or 155VAC unless otherwise specified. Total load must not
exceed 30A per relay.
‡ Use ungrounded frame for AC loads of 5A or greater. Max.ratings are 7.5A at 115VAC and
4A at 28VDC for coil codes S and J.
§ Use ungrounded frame for AC loads of 5A or greater. Max.ratings are 5A at 115VAC and 3A
at 28VDC for coil codes S and J.
UL Horsepower Contact Ratings (Coil Code V Only)
Contact Code
W
X
No. of Poles
1, 2, 4
1, 2, 4, 6
At 110-120VAC
1/8 HP (3.8A)
1/20 HP (1.5A)
At 220-240VAC
1/6 HP (2.2A)
1/10 HP (1.5A)
Expected Mechanical Life: 100 million operations, typical. (Except contact
Code W: 1,000,000 operations, typical.)
Typical Expected Life For Resistive Loads @ 25°C
Type Current
Voltage
Contact Style Coil Code Operations††
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10S
R10
R10
R10S
R10
R10
R10
R10
R10S
R10
R10S
R10
7.5A
7.5A
5.0A
5.0A
4.0A
3.0A
3.0A
2.0A
2.0A
2.0A
1.0A
1.0A
1.0A
500mA
100mA
100mA
100mA
100mA
50mA
30mA
1mA
120VAC, 60 Hz.
28VDC
120VAC, 60 Hz.
28VDC
28VDC
28VDC
28VDC or 120VAC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC or 120VAC
48VDC
6VDC
28VDC or 120VAC
6VDC
6VDC
6VDC
W
W
X
X
W
X
P
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Z
P
P,Y,Z
P,Z
P,Z
P
V,S,J
V
V,S,J
V
S,J
S,J
V,S,J
V
S,J
J
V,S,J
SS,JJ
J
SS,JJ
V,S,J
SS,JJ
SS,JJ
J
V,S,J
J
SS,JJ
7.5 · 104
7.5 · 104
5 · 104
5 · 104
2 · 104
2 · 104
3 · 104
1.5 · 106
6 · 105
5 · 105
12 · 106
5 · 105
1 · 106
5 · 106
1 · 108
5 · 106
5 · 107
1 · 106
5 · 107
5 · 106
5 · 107
†† Relay operated at rated coil voltage or 133% of pick-up current or higher.
www.DataSheet4U.com
Initial Dielectric Strength
Between Open Contacts: 500V rms, for contact codes P and Z.
1,000V rms for contact codes W, X and Y with
coil code V.
Between All Other Conductors: 1,000V rms.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Capacitance
Between Contacts: 2 pf, typ.
Between Contacts and Coil: 2 pf, typ.
Between Coil and Frame: 30 pf, typ.
Initial Insulation Resistance
Between Mutually Insulated Elements: 1010 ohms @ 25°C, 50% RH.
Consult factory for optional acetal resin material rated 1012 ohms.
Coil Data @ 25°C (also see Coil Data tables)
Voltage: 3 to 115VDC and 6 to 115VAC.
Maximum Coil Power: 2.2 Watts.
Coil Temperature Rise: 30°C per Watt.
Maximum Coil Temperature: 105°C.
Operate Data @ 25°C
R10 Relays (DC Only) Typical Ranges of Operations
(Curves for reference only. If specific
values are required, testing is required.)
30 12
25
Typical Operate
10
and Release Time
(all contact configurations)
20 8
15 6
Release Time
(no suppression)
10 4
5
Operate Time
2
1.0 1.33 1.5 2.0 2.5 3.0
Multiple of Max. Pull-In Voltage or Current
R10 Ultra-Sensitive "SS" and "JJ" Typical Ranges of Operation
(Curves for reference only. If specific
values are required, testing is required.)
50 10
Typical Operate
40
and Release Times
8
(all contact configurations)
30 6
Release Time
20 (no suppression) 4
10 Operate Time 2
1.0 1.5 2.0 3.0 4.0
Multiple of Max. Pull-In Voltage or Current
Environmental Data
Storage Temperature Range: -55°C to +105°C.
Operating Temperature Range: -55°C to +75°C.
Mechanical Data
Terminal Finish: Tin plating standard.
Weight: 0.8 to 1.4 oz. (23 to 40g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
703
Refer to inside back cover.


R10-Exxx-xxxx 데이터시트, 핀배열, 회로
www.DataSheet4U.com
Catalog 1308242
Issued 3-03
P&B
Coil Data Tables @ 25°C
One of the boldface resistance or voltage values from a table below is to be inserted in step 6 of the ordering chart on the next page.
V Standard DC Voltage Adjustment
2.2 Watts Maximum Continuous Coil Dissipation @ 25°C
VDC at 25°C
Nominal
Pick-up
(Max.)
Coil Resistance
at 25°C ± 10% (ohms)
1, 2 & 4 Form
6 Form A,
8 Form A,
A, B, C or D
Pick-up
B or C
Pick-up
B or C
Pick-up
500mW
850mW
1000mW
3.0
5.0
6.0
12.0
24.0
48.0
72.0
115.0
2.25
3.75
4.5
9.0
18.0
36.0
54.0
86.0
10
28
52
185
700
2.5K
5.8K
15.0K
6
16
25
90
430
1.5K
3.5K
9.0K
5
14
20
72
350
1.25K
2.8K
8.0K
Q Special DC Voltage Adjustment
1 & 2 Form A, B, C or D
3 & 4 Form A, B, C or D
Coil Res.
@ 25°C
± 10%
(ohms)
Pick-up
(Max.)
@ 25°C
(VDC)
Pick-up
@ 25°C
(mW)
Coil Res.
@ 25°C
± 10%
(ohms)
Pick-Up
(Max.)
@ 25°C
(VDC)
Pick-Up
@ 25°C
(mW)
52 3.1 180
32
110 4.5 185
52
450 9.2 190
185
1.8K
17.4
170
1.0K
7.5K
36.2
175
3.2K
15.0K
49.5
165
7.5K
30.0K
67.5
160
15.0K
3.8 450
4.2 340
8.4 380
17.2 295
31.1 300
49.3 325
67.5 300
Nominal
Voltage
@ 25°C
(VDC)
5
6
12
24
48
72
115
S Sensitive DC Voltage Adjustment
2.2 Watts Maximum Continuous Coil Dissipation @ 25°C
VDC at 25°C
Coil Resistance
at 25°C ± 10% (ohms)
Nominal
Pick-up
(Max.)
1 & 2 Form
A, B, C or D
Pick-up
100mW
3 & 4 Form A,
B, C or D
Pick-up
175mW
6 Form A,
B or C
Pick-up
250mW
3.0
5.0
6.0
12.0
24.0
48.0
72.0
115.0
2.25
3.75
4.5
9.0
18.0
36.0
54.0
86.0
50
140
200
800
3.2K
13.0K
28.0K
50.0K
30
80
110
450
1.8K
7.5K
16.0
40.0K
20
56
80
320
1.2K
5.2K
13.0K
30.0K
8 Form A,
B or C
Pick-up
400mW
12
35
52
200
800
3.2K
7.5K
16.0K
J Sensitive DC Current Adjustment
Must Operate Current (mA)
All Applicable Types Except R10S
Coil
Resistance
±10%
(ohms)
2 Form A,
B, C or D
Pick-up
85mW
4 Form A,
B, C or D
Pick-up
175mW
6 Form A,
B, C or D
Pick-up
250mW
8 Form A,
B or C
Pick-up
400mW
1.0K
2.5K
5.0K
10.0K
15.0K
30.0K
8.5
5.8
4.1
3.1
2.6
1.7
13.0 16.0
8.4 10.0
6.2 7.2
4.5 5.0
3.5 4.2
2.5 2.9
R10S Types Only
20.0
13.0
9.0
6.4
5.3
3.7
Coil
Resistance
±10%
(ohms)
1
Form C
Pick-up
10mW
2
Form C
Pick-up
20mW
500
1.0K
2.5K
5.0K
10.0K
16.0K
30.0K
4.5 (A)
3.2 (A)
2.0
1.4 (B)
1.0
0.8
0.6 (C)
6.3 (A)
4.5
2.9 (B)
2.0
1.4 (C)
1.2
0.8
(A) Suggested for 5VDC operation.
(B) Suggested for 12VDC operation.
(C) Suggested for 24VDC operation.
Max.
Coil
Current
(mA)
45.0
28.0
20.0
14.0
11.5
8.3
4
Form C
Pick-up
40mW
9.0
6.5
4.1 (B)
2.9 (C)
2.0
1.4
1.2
JJ
Coil
Resistance
at 25°C
±10%
1.0K
2.5K
5.0K
10.0K
15.0K
30.0K
Ultra-Sensitive Current Adjustment
(1-4 Pole Only)
Maximum Pick-Up Current (mA)
1 Form C
Pick-Up
Power
20mW
2 Form C
Pick-Up
Power
40mW
3 & 4 Form C
Pick-Up
Power
80mW
Maximum
Continuous
Coil Current
(mA)
4.5 6.5
2.9 4.1
2.1 2.9
1.5 2.0
1.2 1.7
0.85 1.2
9.0 45.0
5.8 28.0
4.1 20.0
3.0 14.0
2.4 11.5
1.7 8.3
Standard AC Operated Relays
Coil Resistance
@ 25°C ± 20% (ohms)
Volts AC @ 25°C
2 & 4 Form C 6 & 8 Form C
Pick-Up
(max.)
Nominal
Maximum
Continuous
25
120
500
2.0K
9.0K
15
90
350
1.4K
7.5K
5.0 6
9.0 12
18.0 24
36.0 48
86.0 115
7.2
14.5
30.0
60.0
130.0
Note: Dual coil diode rectified construction.
SS Ultra-Sensitive Voltage Adjustment
(1-4 Pole Only)
2.2 Watts Maximum Continuous Coil Dissipation @ 25°C
VDC at 25°C
Nominal
Pick-up
(Max.)
Coil Resistance
at 25°C ± 10% (ohms)
1 Form C
2 Form C 3 & 4 Form C,
Pick-up
Pick-up
Pick-up
Power
Power
Power
20mW
40mW
80mW
3.0 2.25 220 110
5.0 3.75 700 350
1w62..00ww.Da49..t05aSheet414..00UKK .com
500
2.0K
18.0 13.5
9.0K
4.5K
24.0 18.0
15.0K
7.5K
36.0 27.0
30.0K
15.0K
48.0 36.0
— 30.0K
52
175
250
1.0K
2.2K
3.7K
7.5K
15.0K
Dimensions are shown for
704 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Typical Coil Inductance
500
100
50
10
1.0
0.5
Armature (open)
Armature (closed)
0.1
10
50 100
500 1K
5K 10K 100K
Coil Resistance (Ohms)
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.




PDF 파일 내의 페이지 : 총 6 페이지

제조업체: Tyco

( tyco )

R10-Exxx-xxxx relay

데이터시트 다운로드
:

[ R10-Exxx-xxxx.PDF ]

[ R10-Exxx-xxxx 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


R10-Exxx-xxxx

(R10-Series) General Purpose Dry Circuit AC / DC Relay - Tyco