COSEL |
AC-DC Power Supplies PCB Mount type
Ordering information
YS5
Y S 5 05A
1234
1Series name
R 2Single output
3Output wattage
4Output voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
YS505A
5.0
5V 1.0A
YS512A
5.4
12V 0.45A
SPECIFICATIONS
MODEL
YS505A
YS512A
VOLTAGE[V]
CURRENT[A]
AC85 - 132 1f or DC110 - 170
ACIN 100V 0.15typ (Io=100%)
INPUT
FREQUENCY[Hz]
47 - 440 or DC
EFFICIENCY[%] ACIN 100V 68typ (Io=100%)
INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%)
70typ (Io=100%)
VOLTAGE[V]
5
12
CURRENT[A]
1
0.45
LINE REGULATION[mV] 20max
48max
LOAD REGULATION[mV] 40max
100max
RIPPLE[mVp-p]
*1 80max
120max
OUTPUT
Y
RIPPLE NOISE[mVp-p] *1 120max
TEMPERATURE REGULATION[mV] 0 to +55C 50max
START-UP TIME[ms]
200max (ACIN 85V, Io=100%)
150max
150max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed
OUTPUT VOLTAGE SETTING[%] t5max (Rated input/output, Ta=25 C)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
INPUT-FG, OUTPUT
ISOLATION
OUTPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
-20 to +75C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 30minutes each along X, Y and Z axis
IMPACT
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS
NOISE
REGULATIONS CONDUCTED NOISE
UL60950-1, C-UL
Complies with FCC-B
*1 Measured by 20MHz oscilloscope.
* Parallel operation with other model is not possible.
Y-2
External view
YS5
Performance data
¡STATIC CHARACTERISTICS (YS512A)
¡RISE TIME & FALL TIME (YS512A)
¡OVERCURRENT CHARACTERISTICS (YS512A)
¡DERATING CURVE
20ms/DIV
Y
Y-3
|