Omron |
G4QRatchet Relay
Unique Ratchet Mechanism Assures Positive
Alternate Transfer/Switching Operation
• Each contact in the double-pole contact mechanism performs
alternate make-brake operation at each pulse input and is thus
ideal for alternate operation or transfer/switching operation of a
motor.
• Positive operation is assured due to the unique ratchet mecha-
nism.
• Satisfies dielectric strength of 2,000 VAC.
• Low power consumption.
(AC: approx. 6.4 VA; DC: approx. 3.9 W)
Ordering Information
CSM_G4Q_DS_E_3_2
Open Models
Item
Basic model
Model
G4Q-211A
DPDT
Rated voltage
24 VAC
50 VAC
100/(110) VAC
200/(220) VAC
12 VDC
24 VDC
100 VDC
Plug-in Models
Item
Basic model
Model
G4Q-212S
Note:
When ordering, add the rated coil voltage (listed in Specifications) to the model number.
Example: G4Q-211A, 24 VAC
Rated coil voltage
Model Number Legend
G4Q-@@@@
1 23 4
1. Contact Form
2: DPDT
2. Contact Type
1: Single
3. Enclosure Construction
1: No casing
2: Casing
4. Terminal Shape
A: Solder
S: Plug-in
DPDT
Rated voltage
12 VAC
24 VAC
50 VAC
100/(110) VAC
200/(220) VAC
12 VDC
24 VDC
100 VDC
200 VDC
1
■ Accessories (Order Separately)
DIN track/Front-connecting Socket
Screw terminal
8PFA1
Back-connecting Socket
Solder terminal
PL08
G4Q
Specifications
■ Coil Ratings
Item
Current (mA)
Rated voltage (V) 50 Hz 60 Hz
AC 12 614 531
24 307 266
50 148 128
100/
(110)
74
64/73.5
200/
(220)
37
32/36.8
Resistance (Ω) Must operate Must release Max. voltage
% of rated voltage
2.24
80 % max.
10 % min.
110 % max.
8.7
42.7
160
671
Power consumption
Initial
Rated
Approx.
13.5 VA
Approx.
6.4 VA
Item
Current (mA)
Rated voltage (V) 50 Hz 60 Hz
DC 12
320
24 155
Resistance (Ω) Must operate Must release Max. voltage
% of rated voltage
37.5 5 % min.
155
Power consumption
Approx. 3.9 W
100 39
2,580
200 19.2
10,400
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
±15% for DC coil resistance.
2. The AC coil resistance values are for reference only.
3. Performance characteristic data is measured at a coil temperature of 23°C.
4. The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.
5. The AC power consumption is measured at 60 Hz.
■ Contact Ratings
Load
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Resistive load
(cosφ = 1)
Single
Silver alloy
5 A at 220 VAC, 5 A at 24 VDC
5A
250 VAC, 250 VDC
5A
Inductive load
(cosφ = 0.4)
(L/R = 7 ms)
3 A at 220 VAC, 4 A at 24 VDC
2
|