Formosa MS |
( DataSheet : www.DataSheet4U.com )
DI101 THRU DI107
SINGLE PHASE 1.0 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
1.0 Ampere
FEATURES
* Ideal for printed circuit board
* Reliable low cost construction utilizing molded
plastic technique
* High surge current capability
* Polarity: marked on body
* Mounting position: Any
* Weight: 1.0 grams
DB-1
+
~~
.365(9.3)
.355(9.0)
.020
(0.5)
.205(5.2)
.195(5.0)
.255(6.5)
.245(6.2)
.135(3.4)
.115(2.9)
.165(4.2)
.155(3.9)
.060
1.5
.350(8.9)
.300(7.6)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=40 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 1.0A D.C.
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Operating Temperature Range, TJ
Storage Temperature Range, TSTG
Ta=125 C
DI101
50
35
50
DI102
100
70
100
DI103
200
140
200
DI104
400
280
400
DI105
600
420
600
1.0
50
1.1
10
500
-65 +125
-65 +150
DI106
800
560
800
DI107
1000
700
1000
UNITS
V
V
V
A
A
V
mA
mA
C
C
www.DataSheet4U.com
RATING AND CHARACTERISTIC CURVES (DI101 THRU DI107)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
1.2
1.0
0.8
0.6 Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
0.4
0.2
0
0 25 50 75 100 125 150 175
CASE TEMPERATURE,( C)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
50
40
30
20
10
0
1
Tj=25 C
8.3ms Single Half
Sine Wave
JEDEC method
5 10
NUMBER OF CYCLES AT 60Hz
50 100
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
50
10
3.0
1.0
0.1
Tj=25 C
Pulse Width 300us
1% Duty Cycle
.01
0
.2 .4 .6 .8 1.0 1.2 1.4
FORWARD VOLTAGE,(V)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
50
10
3.0
1.0
0.1
Tj=25 C
.01
0 20 40 60 80 100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
|