Micro Commercial Components |
MCC
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
W005M
THRU
W10M
Features
• Low Profile Package
• Any Mounting Position
• Silver Plated Copper Leads
• Surge Overload Rating Of 50 Amps
1.5 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Maximum Ratings
• Operating Temperature: -55°C to +125°C
• Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
W005M
W01M
W02M
W04M
W06M
W08M
W10M
Device
Marking
W005M
W01M
W02M
W04M
W06M
W08M
W10M
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000v
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
IF(AV)
1.5A TJ = 25°C
Peak Forward Surge
Current
IFSM
50A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
VF 1.0V IFM = 1.5A;
TJ = 25°C*
Maximum DC
Reverse Current At IR 10µA TJ = 25°C
Rated DC Blocking
1mA TJ = 100°C
Voltage
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
WOM
A
B
C
D
F
AC
+
-
AC
E
E
DIMENSIONS
INCHES
DIM MIN
MAX
A ---- .358
B ---- .225
C 1.000
---
D 1.200
---
E .180 .220
F .030 .032
MM
MIN
------
------
25.40
30.50
4.60
0.76
MAX
9.10
5.70
---
---
5.60
0.81
NOTE
www.mccsemi.com
W005M thru W10M
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
Amps 1
.6
.4
TJ=25°C
.2
.1
.06
.04
.02
.01
.2 .4 .6 .8 1.0 1.2 1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Forward Derating Curve
1.8
1.5
1.2
.9
Amps
.6
.3
Single Phase, Half Wave
60Hz Resistive or Inductive Load
020 40 60 80 100 120 140
°C
Average Forward Rectified Current - Amperesversus
Ambient Temperature -°C
MCC
Figure 2
Typical Reverse Characteristics
10
6
4
2
1
.6
.4
.2
µAmps .1
.06
.04
.02
.01
.006
.004
TJ=25°C
.002
.001
20 40 60 80 100 120 140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 4
Peak Forward Surge Current
60
50
40
30
Amps
20
10
0
12
4 6 8 10 20
Cycles
40 60 80 100
00
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
|