Features
• Mounting Hole For #6 Screw
• Plastic Case
• Any Mounting Position
• Surge Rating Of 50 Amps
• Low Forward Voltage Drop
Maximum Ratings
• Operating Temperature: -55°C to +125°C
• Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
PB305
PB31
PB32
PB34
PB36
PB38
PB310
Device
Marking
PB305
PB31
PB32
PB34
PB36
PB38
PB310
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
35V
70V
140V
280V
420V
560V
700V
50V
100V
200V
400V
600V
800V
1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
IF(AV)
3.0A TC = 50°C
Peak Forward Surge
Current
IFSM
50A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
VF 1.2V IFM = 1.5A per
element;
Maximum DC
TJ = 25°C
Reverse Current At IR 10µA TJ = 25°C
Rated DC Blocking
1 mA TJ = 100°C
Voltage
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
3 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
PB-3
B
C
E
D
G
+ AC
AC -
A
A
DIMENSIONS
INCHES
DIM MIN
MAX
A .580 .620
B .230 .270
C .750
---
D .405 .445
E .028 .032
G .140 .150
MM
MIN
14.69
5.84
19.00
10.29
0.71
3.56
MAX
15.71
6.86
---
11.31
0.81
3.81
NOTE
2PL
2PL
4PL/TYP
∅
www.mccsemi.com
PB305 thru PB310
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
Amps 1
.6
.4
25°C
.2
.1
.06
.04
.02
.01
.2 .4 .6 .8 1.0 1.2 1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Forward Derating Curve
3.0
2.5
2.0
1.5
Amps
1.0
.5
Single Phase, Half Wave
60Hz Resistive or Inductive Load
00 25 50 75 100 150 175
°C
Average Forward Rectified Current - Amperesversus
Ambient Temperature -°C
MCC
Figure 2
Typical Reverse Characteristics
10
6
4
2
1
.6
.4
.2
µAmps .1
TJ=25°C
.06
.04
.02
.01
.006
.00
4
.002
.001
20 40 60 80 100 120 140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 4
Maximum Non-Repetitive Forward Surge Current
60
50
40
30
Amps
20
10
0
12
4 6 8 10 20
Cycles
40 60 80 100
00
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
|