Micro Commercial Components |
MCC
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
RS1001
THRU
RS1007
Features
• Low Leakage
• Low Forward Voltage
• Any Mounting Position
• Silver Plated Copper Leads
10 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Maximum Ratings
• Operating Temperature: -55°C to +150°C
• Storage Temperature: -55°C to +150°C
Microsemi
Catalog
Number
RS1001
RS1002
RS1003
RS1004
RS1005
RS1006
RS1007
Device
Marking
RS1001
RS1002
RS1003
RS1004
RS1005
RS1006
RS1007
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000v
RS-6
A
D
E
BC
-A
+
G
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
IF(AV)
10 A TJ = 65°C
Peak Forward Surge
Current
IFSM
300A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
VF 1.1V IFM = 5.0A;
TJ = 25°C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 10µA TJ = 25°C
100mA TJ = 100°C
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
FH
J
K
L
DIMENSIONS
INCHES
DIM MIN
MAX
A --- .925
B --- .763
C --- .680
D .15∅ x .23L
E --- .300
F --- .157
G 1.00
---
H --- .050
J --- .280
K --- .075
L --- .200
MM
MIN
---
---
---
3.8∅ x
---
---
25.40
---
---
---
---
MAX
23.50
19.40
17.20
5.57L
7.50
4.00
---
1.30
7.00
1.90
5.10
NOTE
NOM
HOLE
NOM
NOM
TYP
NOM
3PL
www.mccsemi.com
RS1001 thru RS1007
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
Amps 1
.6
.4
25°
C
.2
.1
.06
.04
.02
.01
.2 .4 .6 .8 1.0 1.2 1.3
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Forward Derating Curve
12
10
8
6
Amps
4
2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
020 40 60 80 100 120 140
°C
Average Forward Rectified Current - Amperesversus
Ambient Temperature -°C
Figure 2
Typical Reverse Characteristics
10
6
4
TJ=100°C
2
1
.6
.4
.2
µAmps .1
.06
.04
TJ=25°C
.02
.01
.006
.00
4
.002
.001
20 40 60 80 100 120 140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 4
Peak Forward Surge Current
300
250
200
150
Amps
100
50
0
12
4 6 8 10 20
Cycles
40 60 80 100
00
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles