Agilent(Hewlett-Packard) |
H
T-1 (3 mm) Diffused
LED Lamps
Technical Data
HLMP-130X Series
HLMP-1385
HLMP-140X Series
HLMP-1485
HLMP-1503
HLMP-1523
HLMP-1585
HLMP-K40X Series
HLMP-K600
Features
• High Intensity
• Choice of 4 Bright Colors
High Efficiency Red
Orange
Yellow
High Performance Green
• Popular T-1 Diameter
Package
• Selected Minimum
Intensities
• Wide Viewing Angle
• General Purpose Leads
Package Dimensions
1-134
• Reliable and Rugged
• Available on Tape and Reel
Description
This family of T-1 lamps is widely
used in general purpose indicator
applications. Diffusants, tints, and
optical design are balanced to
yield superior light output and
wide viewing angles. Several
intensity choices are available in
each color for increased design
flexibility.
Part
Number
HLMP-
1300
1301
1302
1385
K400
K401
K402
1400
1401
1402
1485
1503
1523
1585
K600[1]
Application
General Purpose
General Purpose
High Ambient
Premium Lamp
General Purpose
High Ambient
Premium Lamp
General Purpose
General Purpose
High Ambient
Premium Lamp
General Purpose
High Ambient
Premium Lamp
General Purpose
Minimum
Intensity
(mcd) at 10 mA
1.3
2.1
3.4
8.6
1.3
2.1
3.4
1.4
2.2
3.6
5.7
1.0
2.6
4.2
1.0
Color
(Material)
High Efficiency
Red
(GaAsP on
GaP)
Orange
(GaAsP on
GaP)
Yellow
(GaAsP on
GaP)
Green
(GaP)
Emerald Green
(GaP)
Note:
1. Please refer to Application Note 1061 for information comparing standard green and
emerald green light output degradation.
5964-9374E
Absolute Maximum Ratings at TA = 25°C
Parameter
Peak Forward Current
Average Forward Current[1]
DC Current[2]
Reverse Voltage (IR = 100 µA)
Transient Forward Current[4]
(10 µsec Pulse)
LED Junction Temperature
Operating Temperature Range
HER/Orange
90
25
30
5
500
110
-55 to +100
Yellow
60
20
20
5
500
Green
90
25
30
5
500
110
-55 to +100
110
-20 to +100
Units
mA
mA
mA
V
mA
°C
°C
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
-55 to +100
260°C for 5 seconds
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
Electrical Characteristics at TA = 25°C
Symbol
Description
Device
HLMP-
IV Luminous Intensity
High Efficiency Red
1300
1301
1302
1385
Orange
K400
K401
K402
Yellow
1400
1401
1402
1485
Green
1503
1523
1585
Emerald Green
K600
Test
Min. Typ. Max. Units Conditions
1.3 5.0
2.1 5.5
3.4 7.0
8.6 11.0
mcd IF = 10 mA
1.3 5.0
2.1 5.5
3.4 7.0
1.4 5.0
2.2 6.0
3.6 7.0
5.7 10.0
1.0 5.0
2.6 7.0
4.2 8.5
1.0 4.5
1-135
|