파트넘버.co.kr RF1238 데이터시트 PDF


RF1238 반도체 회로 부품 판매점

SAW Filter



RF Monolithics 로고
RF Monolithics
RF1238 데이터시트, 핀배열, 회로
www.DataSheet4U.com
®
• Ideal Front-End Filter for 318.0 MHz Wireless Receivers
• Low-Loss, Coupled-Resonator Quartz Design
• Simple External Impedance Matching
• Rugged TO39 Hermetic Package
• Complies with Directive 2002/95/EC (RoHS) Pb
The RF1238 is a low-loss, compact, and economical surface-acoustic-wave (SAW) filter designed to provide
front-end selectivity in 318.0 MHz receivers. Receiver designs using this filter include superhet with
10.7 MHz or 500 kHz IF, direct conversion and superregen. Typical applications of these receivers are wire-
less remote-control and security devices operating in the USA under FCC Part 15, in Canada under DoC
RSS-210, and in Australia.
This coupled-resonator filter (CRF) uses selective null placement to provide suppression, typically greater
than 40 dB, of the LO and image spurious responses of superhet receivers with 10.7 MHz IF. RFM’s ad-
vanced SAW design and fabrication technology is utilized to achieve high performance and very low loss with
simple external impedance matching (not included). Quartz construction provides excellent frequency stability
over a wide temperature range.
RF1238
318.0 MHz
SAW Filter
TO39-3 Case
Electrical Characteristics
Characteristic
Nominal Frequency at 25°C Absolute Frequency
Insertion Loss
Tolerance from 318.0 MHz
3 dB Bandwidth
Rejection
at fC - 21.4 MHz (Image)
at fC - 10.7 MHz (LO)
Ultimate
Temp. Characteristics
Operating Case Temp.
Turnover Temperature
Turnover Frequency
Freq. Temp. Coefficient
Frequency Aging
External Impedance Match Series Inductance
Shunt Capacitance (Tab Side, Non Tab Side)
Lid Symbolization (in addition to Lot and/or Date Codes)
Sym
fC
fC
IL
BW3
TC
TO
fO
FTC
IfAI
L
C
Notes
1, 2
1
1, 2
1
3, 4
5
1
Minimum
Typical
Maximum
318.0
±80
1.7 3.5
500 700 800
40 50
15 40
80
-40 +85
30 45 60
fC+4
0.032
10
86
6.8 on Pin 1 Side, 4.7 on Pin 2 Side
RFM RF1238
Units
MHz
kHz
dB
kHz
dB
°C
°C
kHz
ppm/°C2
ppm/yr
nH
pF
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture which is connected to a 50 test system with
VSWR 1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter center frequency, fc. Note that insertion loss, bandwidth,
and passband shape are dependent on the impedance matching component values and quality.
2. The frequency fc is defined as the midpoint between the 3dB frequencies.
3. Where noted, specifications apply over the entire specified operating temperature range.
4. The turnover temperature, TO, is the temperature of maximum (or turnover) frequency, fo. The nominal frequency at any case temperature, Tc, may
be calculated from: f = fo [1 - FTC (To - Tc)2].
5. Frequency aging is the change in fc with time and is specified at +65°C or less. Aging may exceed the specification for prolonged temperatures
above +65°C. Typically, aging is greatest the first year after manufacture, decreasing significantly in subsequent years.
6. The design, manufacturing process, and specifications of this device are subject to change without notice.
7. One or more of the following U.S. Patents apply: 4,54,488, 4,616,197, and others pending.
8. All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale.
RF Monolithics, Inc. Phone: (972) 233-2903
Fax: (972) 387-8148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1999 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
http://www.rfm.com
RF1238-102401
Page 1 of 2


RF1238 데이터시트, 핀배열, 회로
318.0 MHz
SAW Filter
Absolute Maximum Ratings
Rating
Incident RF Power
DC Voltage Between Any Two Pins (Observe ESD Precautions)
Case Temperature5
Value
+13
±30
-40 to +85
Units
dBm
VDC
°C
Typical Filter Response
Typical filter responses are shown below. The actual response is dependent on external impedance matching and circuit layout. Illustrated frequencies
and minimum rejection for LO and IMAGE are shown only for superhet receivers with 10.7 MHz IF.
.
0
dB
-10
LO
-20
0
dB
-1
-2
-30
-40 Image
-50
-60
-3
-4 Minimum 3dB
Passband
-5 at 25oC
-6
-70 -7
-80
5 MHz/div
Frequency
-8
100 KHz/div
Frequency
Electrical Connections
Pin Connection
1 Input or Output
2 Output or Input
3 Case Ground
Typical Test Circuit
Bottom View
Pin 1
Pin 2
Pin 33
Case Design
C
B
G
F
AE
D
(3 places)
J
(2 places)
H
45°
From 50
Network
Analyzer
L
1
C
L
2
3C
To 50
Network
Analyzer
Dimensions
A
B
C
D
E
F
G
H
J
Millimeters
Min Max
9.40
3.18
2.50 3.50
0.46 Nominal
5.08 Nominal
2.54 Nominal
2.54 Nominal
1.02
1.40
Inches
Min Max
0.370
0.125
0.098
0.138
0.018 Nominal
0.200 Nominal
0.100 Nominal
0.100 Nominal
0.040
0.055
RF Monolithics, Inc. Phone: (972) 233-2903
Fax: (972) 387-8148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1999 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
http://www.rfm.com
RF1238-102401
Page 2 of 2




PDF 파일 내의 페이지 : 총 2 페이지

제조업체: RF Monolithics

( rfm )

RF1238 filter

데이터시트 다운로드
:

[ RF1238.PDF ]

[ RF1238 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


RF1238

SAW Filter - RF Monolithics



RF1238B

SAW Filter - RF Monolithics