EPCOS |
2-Line Filters
for Converters and Power Electronics
Power line filters for single-phase systems
Rated voltage 250 V~, 50/60 Hz
Rated current 8 A to 25 A
Construction
s Two-line filter
s Metal case
Features
s Very high insertion loss
due to two-stage construction
s Low leakage current
s Easy to install
s Degree of protection: IP 201)
s Design complies with
EN 133 200, UL 1283, CSA 22.2 No.8 1986
s Optimized for long motor cables
and operation under full load
Applications
www.DataSheet4sU.coFmrequency converters for motor drives, e.g.
– elevators
– conveyor systems
– pumps
– traction systems
– HVAC systems (heating, ventilation and air conditioning)
s Power supplies
Terminals
s Safe-to-touch terminal blocks
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
rated temperature, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
B84142-B*-R
1) In accordance with IEC 60529: 1989; EN 60529: 1991; DIN VDE 0470-1
179 03/01
2-Line Filters
for Converters and Power Electronics
Typical circuit diagram
LINE
L
B84142-B*-R
LOAD
L’
N N’
SSB0772-K
Technical data
Rated voltage VR
Rated current IR
Test voltage VP
Overload capability
Leakage current Ileak
Climatic category
250 V~, 50/60 Hz
Referred to 40 °C ambient temperature
1770 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
1,5 · IR for 3 min per hour or
2,5 · IR for 30 s per hour
at 250 V~, 50 Hz
25/100/21 (– 25 °C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
IR
Terminal
Ileak
cross section
A
mm2
mA
8 4 < 3,5
12 4 < 3,5
16 4 < 3,5
25 10 < 3,5
Rtyp
mΩ
42
30
21
9
Approx.
weight
kg
1,35
1,45
1,45
3,7
Ordering code
B84142-B8-R
B84142-B12-R
B84142-B16-R
B84142-B25-R
180 03/01
|