EPCOS |
2-Line Filters
for General-Purpose Applications
Power line filters for single-phase systems
Rated voltage 250 V~, 50/60 Hz
Rated current 1 to 6 A
Construction
s Filter with IEC connector, fuse holder
and switch
s Appliance connector as per IEC 60320
s Fuse holder 5 × 20 mm
s 2-pole disconnector
Features
s Enhanced differential-mode insertion loss
s For installation in instrument housings
Applications
s Medium-performance switch-mode power supplies
s Industrial electronics
s Measuring instruments
www.DataSheet4TUe.cromminals
s Tab connector 6,3 x 0,8 mm at output
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Circuit diagram
LINE
L
LOAD
L’
N N’
SSB0207-F
196 03/01
B84103
2-Line Filters
for General-Purpose Applications
B84103
Technical data
Rated voltage VR
Rated current IR
Test voltage VP
Leakage current l leak
Climatic category
Weight
250 V~, 50/60 Hz
Referred to 40 °C ambient temperature
1414 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
< 1 mA at 230 V~, 50 Hz
In accordance with EN 60068-1
25/085/21 (– 25 °C/+ 85 °C/21 days damp heat test)
approx. 150 g
Characteristics and ordering codes
IR CR
LR
A
1 0,33 µF (X2) + 2 × 9 mH +
2 × 10 nF (Y2)
2 × 270 µH
3 0,33 µF (X2) + 2 × 1,5 mH +
2 × 10 nF (Y2)
2 × 22 µH
6 0,33 µF (X2) + 2 × 0,47 mH +
2 × 10 nF (Y2)
2 × 8 µH
× = approval granted
Ordering code
B84103-S1-A10
Approvals
565-3
×
×
B84103-S1-A30 ×
—
B84103-S1-A60 ×
—
×
×
×
197 03/01
|