Oki Semiconductor |
www.DataSheet4U.com
1 Electronic Components
KGL4126F
10.7 Gbps Mach-Zehnder Modulator Driver IC
FEATURES
• High Output Voltage: Maximum Amplitude > 5.0 Vpp
• X-Point Control Function
• Output Amplitude Control Function
FUNCTION DIAGRAM
November 6, 2002
GTD-18442 Rev. 5.0
INB
IN
VB1 VB2
VS
VC1
OUT
ABSOLUTE MAXIMUM RATINGS
Parameter
Supply Voltage
X-Point Control Voltage
Output Amplitude Control Voltage
DC Bias for Output Stage Amplifier
Operating Temperature at Package Base
Storage Temperature
Symbol
VS
VB1
VC1
VD
Ts
Tst
Min
-6.5
VS-4.5
(Min. -6.5)
-6.5
0
-10
-40
Max
0.3
VS+2.4
(Max. 0.3)
VS+1.2
(Max. 0.3)
5.0
100
125
RECOMMENDED OPERATING CONDITIONS
Unit
V
V
V
V
°C
°C
Note
Parameter
Symbol
Min
Typ
Max Unit
Supply Voltage
VS -5.46
-4.94
V
Supply Voltage*1,2
VD 2.0
3.5 V
X-Point Control Voltage
VB1 VS+0.8
VS+2.2
V
Output Amplitude Control Voltage*1
VC1 VS
VS+1.0
V
Operating Temperature at Package Base
Ts
0
85 °C
Input Interface
AC coupled (External blocking capacitor is required)
Output Interface
AC coupled (External Bias-T is required for VD)
*1 Output Amplitude can be controlled by VC1 and VD voltage. We recommend to control output amplitude by
VD voltage. ( VD is more effective than VC1. )
*2 VD is supplied at Output Port using External Bias-T.
1/9
www.DataSheet4U.com
1 Electronic Components
GTD-18442 Rev. 5.0
KGL4126F
ELECTRICAL CHARACTERISTICS
Parameter
Symbol
Condition
Min Typ Max Unit
Input Data Rate
NRZ
10.7
Gbps
Supply Current of VS
Iss
210 250 mA
Supply Current of VD
ID Supply DC Bias by Bias-T
70 100 mA
Input Amplitude
Vin
Differential (AC Coupled)
0.25
1 Vpp
Single-Ended (AC Coupled) 0.5
1 Vpp
Output Amplitude (Max) Vo (Max) 50 Ω load,(AC Coupled)
5.0
Vpp
X-Point Control
Xp
NRZ, 50 Ω load
40
60 %
Output Rise/Fall Time
Tr/Tf
50 Ω load
20%-80%
40 ps
Input Return Loss
S11 100kHz–10 GHz
13 dB
PACKAGE DIMENSIONS
5.08
20-0.3
16-1.27
15 11
16 KGL4126F
1
JAPAN
XXX
20
10
6
1
9.6
5
12±0.2
11 2
PINCONNECTION
(Top View)
No. Symbol
Note
1 GND Ground
2 GND Ground
3 GND Ground
4 GND Ground
5 GND Ground
6 GND Ground
7 GND Ground
8 GND Ground
9 OUT. Signal Output and DC Bias Port
10 GND Ground
11 GND Ground
12 VC1 Output Amplitude Control Port
13 VS Supply Voltage Port
14 VB2 Input Termination Port
15
VB1
X-Point Control and Inverted
Input Termination Port
16 GND Ground
17 INB Inverted Input Terminal
18 GND Ground
19 IN Signal Input Terminal
20 GND Ground
(Unit : mm)
2/9
|