IXYS |
WESTCODE
An IXYS Company
Date:- 13 Apr, 2004
Data Sheet Issue:- 1
Fast Recovery Diode
Type M1010NC400 to M1010NC450
Old Type No.: SM30-45CXC604
Absolute Maximum Ratings
VRRM
VRSM
VOLTAGE RATINGS
Repetitive peak reverse voltage, (note 1)
Non-repetitive peak reverse voltage, (note 1)
MAXIMUM
LIMITS
4000-4500
4100-4600
UNITS
V
V
IF(AV)M
IF(AV)M
IF(AV)M
IF(RMS)
If(d.c.)
IFSM
IFSM2
I2t
I2t
Tj op
Tstg
OTHER RATINGS
Maximum average forward current, Tsink=55°C, (note 2)
Maximum average forward current. Tsink=100°C, (note 2)
Maximum average forward. Tsink=100°C, (note 3)
Nominal RMS forward current, Tsink=25°C, (note 2)
D.C. forward current, Tsink=25°C, (note 4)
Peak non-repetitive surge tp=10ms, VRM=60%VRRM, (note 5)
Peak non-repetitive surge tp=10ms, VRM≤10V, (note 5)
I2t capacity for fusing tp=10ms, VRM=60%VRRM, (note 5)
I2t capacity for fusing tp=10ms, VRM≤10V, (note 5)
Operating temperature range
Storage temperature range
Notes:-
1) De-rating factor of 0.13% per °C is applicable for Tj below 25°C.
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 150°C Tj initial.
MAXIMUM
LIMITS
1010
668
413
1880
1664
9600
10560
461×103
558×103
-40 to +150
-40 to +150
UNITS
A
A
A
A
A
A
A
A2s
A2s
°C
°C
Data Sheet. Types M1010NC400 to M1010NC450 Issue 1
Page 1 of 11
April, 2004
WESTCODE An IXYS Company
Characteristics
Fast Recovery Diode Types M1010NC400 to M1010NC450
PARAMETER
VFM Maximum peak forward voltage
VT0 Threshold voltage
rT Slope resistance
VFRM Maximum forward recovery voltage
IRRM Peak reverse current
Qrr Recovered charge
Qra Recovered charge, 50% Chord
Irm Reverse recovery current
trr Reverse recovery time, 50% Chord
R
thJK
Thermal resistance, junction to heatsink
F Mounting force
Wt Weight
MIN.
-
-
-
-
-
-
-
-
-
-
-
-
-
19
-
TYP. MAX. TEST CONDITIONS (Note 1)
-
-
-
-
-
-
-
1450
700
440
3.2
-
-
-
510
3.25 IFM=1500A
3.7 IFM=2020A
1.70
1.03
65 di/dt = 1000A/µs, Tj=25°C
160 di/dt = 1000A/µs
150 Rated VRRM
-
950 IFM=1000A, tp=500µs, di/dt=200A/µs,
- Vr=50V, 50% Chord.
-
0.022 Double side cooled
0.044 Single side cooled
26
-
Notes:-
1) Unless otherwise indicated Tj=150°C.
2) For other clamp forces, please consult factory.
UNITS
V
V
mΩ
V
mA
µC
µC
A
µs
K/W
kN
g
Data Sheet. Types M1010NC400 to M1010NC450 Issue 1
Page 2 of 11
April, 2004
|