TR-Electronic |
IEV58-INC-1-GB-1
04/12 Revision 01
i 010101-00589999-9999
+ Incremental interface
+ Type with solid shaft
+ Modular product line
+ Extensive parameter setting possibilities
+ Special parameters upon request
+ Short lead times
+ Further interfaces available
+ Modular construction for mechanical customizations
Characteristics
Supply voltage................................................................................ 11…28 VDC, optional 5 VDC ±5%
Current consumption without load................................................. < 65 mA, < 80 mA at 5 VDC
Number of pulses/revolution 1) ....................................................... ≥2…≤ 1.024, >1.024: 2.048, 4.096, 8.192
Version with push-pull
- Output level .......................................................................... 11…28 VDC, supply voltage
- Output current ...................................................................... ≤ 30 mA
- Output frequency .................................................................. 150 kHz, ±15°
- Supply voltage ...................................................................... 11…28 V DC
Version with line driver
- Output level .......................................................................... 5 VDC, RS422
- Output current ...................................................................... ≤ 50 mA
- Output frequency .................................................................. 300 kHz, ±15°
- Supply voltage ...................................................................... 11…28 V DC, optional 5 VDC
Incremental signals ........................................................................ A+, A–, B+, B–
Zero pulse ...................................................................................... Ref+, Ref–
Programmable parameters
- Number of pulses
- Phase position: A / B, Zero pulse(s)
- Zero pulse: Pulse length, Number of pulses
- Enable/Disable Preset function, Set Ref+, Ref–
Preset ............................................................................................. electronic adjustment of the reference signals Ref+, Ref–
Logic level ...................................................................................... "0“ < + 2 VDC, "1“ = Supply voltage
Mechanically permissible speed ..................................................... ≤ 12.000 min-1
Shaft load, at the shaft end............................................................ ≤ 10 N axial, ≤ 20 N radial
Bearing life time............................................................................. ≥ 3.9 * 1010 revolutions at
- Speed .................................................................................... ≤ 6.000 min-1
- Operating temperature ......................................................... ≤ 60 °C
- Shaft load, at the shaft end................................................... ≤ 5 N axial, ≤ 10 N radial
Permissible angular acceleration.................................................... ≤ 104 rad/s2
Moment of inertia .......................................................................... typically 2.5 * 10-6 kg m2
Start-up torque at 20°C.................................................................. typically 2 Ncm
Mass............................................................................................... 0-3 kg…0-5 kg
1) programmable parameter
Subject to change
www.tr-electronic.de
TR-Electronic GmbH
Eglishalde 6
78647 Trossingen
Tel. +49 7425 228-0
Incremental-Encoder IEV 58
IEV58-INC-1-GB-1
04/12 Revision 01
010101-00589999-9999
Environmental conditions
Vibration, DIN EN 60068-2-6: 1996 .............................................. ≤ 100 m/s2, sine 50-2000 Hz
Shock, DIN EN 60068-2-27: 1995................................................... ≤ 1000 m/s2, half-sine 11ms
EMC
- Immunity to disturbance, DIN EN 61000-6-2: 2006
- Transient emissions, DIN EN 61000-6-3: 2007
Working temperature ..................................................................... 0 °C…+60 °C, optional -20 °C…+70 °C
Storage temperature ...................................................................... -30 °C…+80 °C, dry
Relative humidity, DIN EN 60068-3-4: 2002 .................................. 98 %, non condensing
Protection class, DIN EN 60529: 1991 2)......................................... IP 65
2) valid with screwed on mating connector and / or screwed together cable gland
Dimension drawing
(For project planning please request customized dimensional drawing!)
Subject to change
www.tr-electronic.de
TR-Electronic GmbH
Eglishalde 6
78647 Trossingen
Tel. +49 7425 228-0
|