SAFT |
Li-SO2 primary battery system
BA 5847 B/U
Assembled from 2 LO 26 SX cells
connected in series.
Key features
• A non-replaceable fuse is
incorporated in the negative leg.
• A normally closed thermal fuse
(TCO) is incorporated in the
battery. It is non-replaceable
and non-resetable.
• A diode is incorporated to
prevent charging or flow of
current into the batter y.
• A device consisting of a
manually activated switch and
resistor designed to discharge
the battery to 0 V is built into
the battery.
• Made in the USA
Typical applications
• AN/PRM-34 Radio Tests
• AN/PRS-7 Mine Detection
• AN/TS-54 Night Sight
Electrical Characteristics
Typical OCV (V)
Nominal voltage (at 500mA) (V)
Cut-off (V)
Typical Capacity (Ah) +21 °C / + 70 °F
(at 250 mA discharge current)
Operating temperature
Storage
Recommended max
Possible
6.0
5.3
4.0
7.5
-40° C to 71° C
-40° F to 160° F
+35°C/ +95°F
-40° C to 71° C / -40° F to 160° F
Physical Characteristics
Typical Weight (g/oz)
Weight of Li metal content (g/oz)
Max. Width (mm/ in)
Max. Height (mm/ in)
Max. Depth (mm/ in)
Battery Case
References
Mating Connector
Reference specifications
NSN Reference
240 / 8.47
4.8 / 0.16
95/ 3.78
65 / 2.58
38 / 1.53
Plastic
Keystone Electronics No. 212
MIL PRF 49471B (CR) or Saft Standard Specifications
6135-01-090-5364
March 2006
http://www.Datasheet4U.com
BA 5847 B/U dimensions
*All measurements in inches
Capacity vs rate at various temperatures
2 A discharge typical curves at various temperatur es
Electrical schematic
Typical discharge curves at various rates at +21ºC/+70ºF
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel: +33 (0)1 49 93 19 18
Fax: +33 (0)1 49 93 19 69
313 Crescent Street
Valdese NC 28690 - USA
Tel: +1 (828) 874 4111
Fax: +1 (828) 874 2431
www.saftbatteries.com
Doc N° 31069-2-0306
Data in this document is subject to change without notice and
becomes contractual only after written
confirmation.
|