Número de pieza | IFR6015 | |
Descripción | Ramp Test Set | |
Fabricantes | Aeroflex | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de IFR6015 (archivo pdf) en la parte inferior de esta página. Total 12 Páginas | ||
No Preview Available ! Avionics
IFR 6015 Ramp Test Set
The IFR 6015 is a compact, lightweight and weatherproof unit designed for testing transponder
modes A/C/S, TCAS I, II and Military E-TCAS as well as DME.
• One main user screen for each test mode
• Detachable antenna
• Large display
• Simple user interface
• Lightweight and compact <8 lbs. (3.6 kg)
• Battery 6 hours plus duration
• Fully FAR part 43 appendix F compliant
• European Elementary and Enhanced
Surveillance
The IFR 6015 features an extremely easy to use
interface where every parameter the user com-
monly needs to view is displayed on screen.
Controls
Dedicated Mode keys for XPDR, DME and TCAS
allow quick selection of the operational mode.
The application dependant softkeys and data
select/slew keys provide an intuitive man machine
interface.
DME mode is provided with dedicated keys for
frequency/channel selection and RF level control.
For frequently varied parameters in DME and
TCAS modes, such as Range and Rate, dedicated
keys are provided.
Operational Modes
Each operational mode has one main user screen. The operational
modes are:
XPDR (Sub-Modes: ADS-B MON, ADS-B GEN & GICB)
DME
TCAS 1, 2 (Sub-Modes: TIS & TIS-B)
E-TCAS
Most tests can be completed without leaving the main user screens.
This simplifies the line technician's testing task.
w w w. a e r o f l ex . c o mFor the very latest specifications visit
Free Datasheet http://www.datasheet4u.com/
1 page TIS
Up to 5 static intruders may be simulated relative to the A/C (UUT).
TIS-B:
The user enters the A/C (UUT) LAT/LONG and heading.
Up to 5 static intruders may be simulated relative to the A/C (UUT).
General
Radiated Testing:
The IFR 6015 is supplied with a lightweight fully sealed directional
antenna that may be test set mounted, hand held or tripod mounted.
Direct Connect Testing:
The IFR 6015 may be directly connected to the UUT via a supplied
RF coax cable via the RF I/O port.
Transit Case:
The IFR 6015 is supplied in a rugged plastic transit case which pro-
vides stowage for the test set, directional antenna, RF coax cable,
antenna shield, breakout box, and power supply/charger.
SPECIFICATION
DME MODE SPECIFICATIONS
SIGNAL GENERATOR
A 5-minute warm-up period is required for all specifications.
OUTPUT FREQUENCY
REPLY FREQUENCY
Range
962 to 1213 MHz
Accuracy
± 10 kHz
OUTPUT LEVEL
ANTENNA PORT
Range
-67 to -2 dBm at Antenna port
Resolution
1 dB
Accuracy
± 2 dB
Distance to UUT antenna
6 to 300 ft with supplied antenna
RF I/O PORT
Range
-115 to -47 dBm
Resolution
1 dB
Accuracy
-95 dBm to –47 dBm
± 1 dB
Accuracy
-115 dBm to <-95 dBm ± 2 dB
REPLY PULSE SPACING
P1 to P2
12 µs ± 100 ns (X Channel) @ 50% peak
P1 to P2
30 µs ± 100 ns (Y Channel) @ 50% peak
w w w. a e r o f l ex . c o mFor the very latest specifications visit
5 Page FREQUENCY
Range
1029.900 to 1030.100 MHz
Resolution
1 kHz
Accuracy
± 10 kHz
TCAS BROADCAST INTERVAL
Range
1.0 to 12.0 sec
Resolution
0.1 sec
Accuracy
± 0.2 sec
MISCELLANEOUS INPUT/OUTPUTS
RF I/O
Type
Input/Output
Impedance
50 Ω typical
Maximum Input Level
4 kW peak
10 W average
VSWR
< 1.3:1
ANTENNA
Type
Input/Output
Impedance
50 Ω typical
Maximum Input Level
10 W peak
1/2 W average
VIDEO
Type
Output
Impedance
50 Ω typical
Generate Video Level
1.1 ± 0.4V peak to peak into 50 Ω
Receive Video Level
Proportional to IF level
Baseline
± 0.5V referenced to ground
TEST ANTENNA
VSWR
< 1.5:1
Gain
6 dB, Typical
TIME BASE (TCXO)
Temperature Stability
± 1 ppm
Aging
± 1 ppm per year
Accuracy
± 1 ppm
Test Limit
± 0.3 ppm
BATTERY
Type
Li Ion
Duration
> 4 hrs continuous operation
> 6 hrs, Typical
INPUT POWER (TEST SET)
Input Range
11 VDC to 32 VDC
Power Consumption
55 W Maximum
16 W Nominal at 18 VDC with charged battery
Fuse Requirements
5 A, 32 VDC, Type F
INPUT POWER (SUPPLIED EXTERNAL AC TO DC
CONVERTER)
Input Range
100 to 250 VAC, 1.5 A Max, 47-63 Hz
Mains Supply Voltage Fluctuations
≤ 10% of the nominal voltage
Transient Overvoltages
According to Installation Category II
ENVIRONMENTAL (TEST SET)
Use
Pollution Degree 2
Altitude
≤ 4800 meters
Operating Temperature
NOTE 3 -20°C to 55°C
Storage Temperature
NOTE 4 -30°C to 71°C
Relative Humidity
95% ±5% from 5° to 30°C
75% ±5% from 30° to 40°C
45% ±5% from 40° to 55°C
ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC
CONVERTER)
Use
Indoors
Altitude
≤ 10,000 meters
Operating Temperature
0° to 40°C
Storage Temperature
-20°C to 71°C
w w w. a e r o f l ex . c o mFor the very latest specifications visit
11 Page |
Páginas | Total 12 Páginas | |
PDF Descargar | [ Datasheet IFR6015.PDF ] |
Número de pieza | Descripción | Fabricantes |
IFR6015 | Ramp Test Set | Aeroflex |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |