파트넘버.co.kr 5207719-x 데이터시트 PDF


5207719-x 반도체 회로 부품 판매점

Cable Clamps



Tyco Electronics 로고
Tyco Electronics
5207719-x 데이터시트, 핀배열, 회로
Female Screwlock Kit
Female Screwlock Kits and
Male Screw Retainer Kits
Instruction Sheet
408-7837
03 FEB 09 Rev B
Nut
Lockwasher
Front of Connector
Flat Washers
Screwlock
4.78 mm
[.188 In.]
FEMALE
SCREWLOCK
KIT
5205817-[ ]
5207719-[ ]
5207872-[ ]
THREAD
SIZE
4-40
4-40
M3 x 0.5
THREAD
LENGTH
7.92 [.312]
14.22 [.560]
7.92 [.312]
CONNECTORS
USED WITH
HDP or HDF Metal Shell
or All-Plastic Plugs &
Receptacles
HD or HDF All-Plastic
Plugs & Receptacles
with Integral standoffs
HDP or HDF Metal Shell
or All-Plastic Plugs &
Receptacles
FEMALE
SCREWLOCK
KIT
5207952-[ ]
5745563-[ ]
5747223-[ ]
THREAD
SIZE
THREAD
LENGTH
4-40 6.35 [.250]
4-40 6.35 [.250]
2-56
(Male)
x 4-40
(Female)
14.22 [.560]
CONNECTORS
USED WITH
HD All-Plastic
Right-Angle
Plugs and Receptacles
HDE Metal Shell or
All-Plastic Plugs &
Receptacles
HD or HDF All-Plastic
Plugs & Receptacles
with Integral standoffs
NOTE: Kits used on plastic shell connectors have square nuts instead of hex nuts and lockwashers.
www.DataSheet4U.net
1. INTRODUCTION
Figure 1
2. DESCRIPTION
This instruction sheet covers the assembly of the
Female Screwlock Kits and the Male Screw Retainer
Kits onto AMPLIMITE* connectors.
These kits are designed to secure mating connectors
in panel–mounted or free–hanging applications. For
panel–mount applications, it is recommended that the
female screwlock kit be assembled on the panel–
mounted connector. Read these instructions
thoroughly before assembling either kit.
The screwlock kit contains two identical screwlock
component assemblies. Each assembly consists of
one screwlock, two flat washers, one lockwasher, and
one nut (see Figure 1).
The screw retainer kit contains two identical screw
retainer component assemblies. Each assembly
consists of one retainer and one retainer screw.
NOTE
i
All dimensions on this document are in metric
units [with U.S. customary units in brackets].
Figures and illustrations are for reference only
and are not drawn to scale.
Reasons for reissue are provided in Section 7,
REVISION SUMMARY.
The screwlock kits and the corresponding screw
retainer kits are available in various dimensions, with
applications for a full range of contact sizes on both
metal and plastic connector shells. See Figure 1 table
for female screwlock kits and Figure 2 table for male
screw retainer kits.
E 2009 Tyco Electronics Corporation, Harrisburg, PA
TOOLING ASSISTANCE CENTER 1-800-722-1111
All International Rights Reserved
PRODUCT INFORMATION 1-800-522-6752
TE logo and Tyco Electronics are trademarks.
*Trademark. Other products, logos, and company names used are the property of their respective owners.
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.tycoelectronics.com
1 of 3
LOC B


5207719-x 데이터시트, 핀배열, 회로
Female Screwlock Kits and Male Screw Retainer Kits
Male Screw Retainer Kit
Retainer Clip
(Style 1)
Front of Connector
Flange
Back of Flange
Slot
408-7837
Retainer Clip
(Style 2)
Retainer Screw
Notched Side of
Retainer
Retainer Screw
SCREW
RETAINER
KIT
THREAD
SIZE
CONNECTORS
USED WITH
5205980-[ ]
4-40
Metal Shell HDP
& HDE
5207871-[ ]
M3 x 0.5
Metal Shell HDP
& HDE
5746881-[ ]
4-40
HDF Metal Shell &
All-Plastic
{ Has Phillips head retainer screw
STYLE
RETAINER
CLIP
1
1
1
SCREW
RETAINER
KIT
5745136-[ ]
THREAD
SIZE
4-40
5745647-[ ]
4-40
5787354-[ ] {
4-40
Figure 2
CONNECTORS
USED WITH
Metal Shell HDP
& HDE
HDE All-Plastic
Metal Shell HDP
& HDE
STYLE
RETAINER
CLIP
2
1
1
3. ASSEMBLING SCREWLOCK KITS
Screwlock component assemblies must be installed
on the connectors as follows:
NOTE
i
www.DataSheet4U.net
Recommended torque for the screwlock
assemblies is .45 N D m [4 in.-lb.].
1. For free–hanging application, install two flat
washers on the screwlock and insert the screwlock
through the connector flange. Secure the assembly
with lockwasher and nut.
2. For front–mounted panel applications, install two
flat washers on the screwlock and insert the
screwlock through the connector flange and panel.
Secure assembly with a lockwasher and nut.
3. For rear–panel mounted applications, install as
follows: NO flat washers on screwlock if panel
thickness is 1.52 mm [.060 in.] or greater; ONE flat
washer if panel is 0.66 to 1.52 mm
[.026 to .060 in.] thick; TWO flat washers if panel
thickness is less than 0.64 mm [.025 in.]. Insert
screwlock (with appropriate number of flat washers
installed) through the panel and the connector
flange. Secure with lockwasher and nut.
4. ASSEMBLING SCREW RETAINER KIT
(Figure 2)
Both screw retainer component assemblies must be
installed on the connector. Install each assembly as
follows:
Style 1 Retainer:
1. Align the slotted side of the retainer with the
BACK of connector flange.
2. Slide retainer onto flange and align holes.
3. Thread retainer screw through retainer from
BACK of flange.
Style 2 Retainer:
1. Align the notched side of the retainer with the
FRONT of connector flange.
2. Mount retainer screw onto connector flange.
3. Slide retainer clip around the connector flange
and the mounting screw.
NOTE
i
The clip will snap in place when properly
assembled.
5. ENGAGING CONNECTORS
Align connector mating faces. Push connectors
together until retainer screws are started into
2 of 3
Tyco Electronics Corporation
Rev B




PDF 파일 내의 페이지 : 총 3 페이지

제조업체: Tyco Electronics

( tyco )

5207719-x data

데이터시트 다운로드
:

[ 5207719-x.PDF ]

[ 5207719-x 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


5207719-x

Cable Clamps - Tyco Electronics