AUREL |
TX-SAW / 433 s-Z Transmitter
TX-SAW/433 s-Z
Instruction Manual
SAW Transmitter module with external antenna, for utilisations with ON-OFF modulation of a RF carrier with digital data.
Pin-out
Lot (Week/Year) Code
www.DataSheet4U.com
Connections
Pin 1-4-13
Ground
Pin 2
Input Mod.
Pin 3
Input Mod.
Pin 11
Pin 15
RF output
+V
15
1
GND Connections. To be externally connected to a single ground plate.
(see fig. 3)
TTL 0÷5V type data input with a minimum 5KΩ resistance. Connection
utilized only if the supply to pin 15 is +12V ±10% (see fig. 2)
TTL 0÷5V type data input with a minimum 5KΩ resistance. Connection
utilized only if the supply to pin 15 is +5V ±10% (see fig. 2)
RF output with a characteristic impedence of 50Ω
Connection to the positive pole of the +5V ±10% supply
Max voltage values allowed
Description
Voltage supply (Vs) to pin 15
Max
13,5
Technical features [ETS 300 200]
Unity
V
Remarks
Description
Working frequency centre
Voltage supply (Vs)
Absorbed current
RF output power (E.R.P.)
Output impedance pin 11
RF spurious emissions
Modulation frequency
Input high logic level
Input low logic level
Working temperature
Working temperature [ETS 300 200]
Dimensions
Min
433.82
4.5
4.5
0
-20
-20
Typical Max
433.92 434.02
5 5.5
4
+10
50
-50
4
5 5.5
0.2
+80
+55
38.1 x 13.2 x 3 mm
Unity
MHz
V
mA
dBm
Ω
dBm
kHz
V
V
°C
°C
Remarks
See notes 1 and 2
See note 1
See note 1
See fig. 5
See fig. 5
See Pin-out
Note1: Values have been obtained by applying the test system shown in Fig. 1 and maximum 5,5 V power supply.
Note2: The minimum and maximum showed values are determined by the device’s construction tolerance.
To define the working frequency of the device, add to these values the deviation caused by the thermal variations (see fig. 3).
Note3: To keep the parameters within the limits established by the rules in force, (see para. “Reference Rules”), it is recommended to
supply the circuit with not more than 5,5V and to comply with all the recommendations specified in para “Device usage”.
Messrs AUR°EL declines all responsibilities in case the a.m. recommendations are disregarded.
Technical features are subject to change without notice. AUR°EL S.p.A does not feel responsible for any damage caused by the device’s misuse.
AUR°EL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY
Tel.: +390546941124 – Fax: +390546941660
Rev. A, 19-09-2001
Pag 1 of 5
TX-SAW/433 s-Z
Instruction Manual
The declared technical features have been obtained by applying the following testing system:
Fig. 1
www.DataSheet4U.com
+5V DC
Power
Supplier
Square wave generator :
4 KHz frequency
Out Level 0÷5V
Pin 3
TX-SAW/433 s-Z
Spectrum
analyzer
RF 50 Ω Input
Pin 11
50 Ù
coaxial
cable
connection
Device usage
In order to obtain the performances described in the technical specifications and to comply with the
operating conditions, which characterize the Certification, the transmitter has to be mounted on a printed
circuit, and keep into consideration what follows:
5V dc supply
1. The transmitter must be supplied by a very low voltage source, safely protected against short circuits.
2. Maximum voltage variations allowed: ± 0,5 V.
3. De-coupling, next to the transmitter, by means of a minimum 100.000 pF ceramic capacitor.
Ground
1. It must surround at the best the welding area of the transmitter. The circuit must be double layer, with
throughout vias to the ground planes, approximately each 15 mm.
2. It must be properly dimensioned, especially in the antenna connection area, in case a radiating whip
antenna is fitted in it (an area of approximately 50 mm radius is suggested).
Technical features are subject to change without notice. AUR°EL S.p.A does not feel responsible for any damage caused by the device’s misuse.
AUR°EL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY
Tel.: +390546941124 – Fax: +390546941660
Rev. A, 19-09-2001
Pag 2 di 5
|