DataSheet.es    


PDF GR64 Data sheet ( Hoja de datos )

Número de pieza GR64
Descripción AT Command Manual
Fabricantes Sony 
Logotipo Sony Logotipo



Hay una vista previa y un enlace de descarga de GR64 (archivo pdf) en la parte inferior de esta página.


Total 30 Páginas

No Preview Available ! GR64 Hoja de datos, Descripción, Manual

wwwwww.Da.DtaSahteaeSt4Uh.ecoemt4U.com
GR64 & GS64
AT Command Manual
The AT Command Manual describes the
AT commands that are supported by the
GR64 and GS64 modules.
Note: Any hard copy of this document is for reference only. Due to template and application dependencies the header and footer may fail to display
correct data. It is the responsibility of the user to ensure that they have a correct and valid version. Any outdated hard copy is invalid and must be
removed from possible use.

1 page




GR64 pdf
wwwwww.Da.5Dta.S5ahteaeSt4Uh.ecoeAmtT4*UE.RcSoEmPCM/Analog Audio and RS232 Selection ............................................... 84
5.6 AT*ESIL Silence Command .................................................................................. 85
5.7 AT+CLVL Loudspeaker Volume Level .................................................................. 85
5.8 AT*TTY CTM (Cellular Text Telephone Mode) Support ........................................ 86
6 Data - CSD.......................................................................................................... 87
6.1 AT+CBST Select Bearer Service Type .................................................................. 87
6.2 AT+CRLP Radio Link Protocol ............................................................................ 88
7 Data - GPRS ........................................................................................................ 90
7.1 AT*E2GDV GPRS Data Volume ............................................................................ 90
7.2 AT*E2GC GPRS Class Setting .............................................................................. 91
7.3 AT*E2GAA GPRS Auto Attach Setting................................................................ 92
7.4 AT+CGACT PDP Context Activate or Deactivate ................................................. 93
7.5 AT+CGANS Manual response to a network request for PDP context activation . 94
7.6 AT+CGATT GPRS Attach or Detach .................................................................... 95
7.7 AT+CGAUTO Automatic response to a network request for PDP context activation96
7.8 AT+CGCLASS GPRS Mobile Station Class ............................................................. 97
7.9 AT+CGDATA Enter Data State ............................................................................. 98
7.10
AT+CGDCONT Define PDP Context..................................................................... 99
7.11
AT+CGEREP GPRS Event Reporting .................................................................... 100
7.11.1 +CGEV GPRS Event Reporting........................................................................... 101
7.12
AT+CGPADDR Show PDP Address ..................................................................... 102
7.13
AT+CGEQMIN 3G Quality of Service Profile (Minimum acceptable) .................... 103
7.14
AT+CGEQNEG 3G Quality of Service Profile (Negotiated)................................... 108
7.15
AT+CGEQREQ 3G Quality of Service Profile (Requested).................................... 110
7.16
AT+CGREG GPRS Network Registration Status ................................................. 115
7.17
AT+CGRDATA Send Limited Data Pattern ......................................................... 117
8
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
8.10
8.11
8.12
Data - TCP/IP.................................................................................................... 118
AT*E2IPA IP Activate ........................................................................................ 118
AT*E2IPC IP Socket Close ................................................................................. 120
AT*E2IPO IP Open/Connect.............................................................................. 121
AT*E2IPI IP Info ................................................................................................ 124
AT*E2IPE IP Error.............................................................................................. 125
AT*E2IPL IP listen (server) ................................................................................. 126
AT*E2IPRH IP Resolve Host................................................................................ 128
AT*E2IPS IP Setup IP Parameters........................................................................ 129
AT*ENAD Internet Account Define..................................................................... 131
AT*E2IPACT IP Socket Accept ............................................................................ 134
AT*E2IPEV IP Socket Events ............................................................................... 135
AT*E2IPATO IP Socket ATO Command .............................................................. 136
9 Identification..................................................................................................... 138
13/198 17-LXE 108 566 Uen
5

5 Page





GR64 arduino
wwwwww.Da.DtaSahteaeSt4Uh.ecoeAmtT4UM.acnoumal Version
PA7
PA8
A
PB1
Gx64 Software Version
P1A062 -
P1A068 -
P1A071 -
P1A072 -
1.4 Syntax Description
This section provides a brief description of the syntax used for the GR64 and GS64 AT
command set. See the ITU-T recommendation V.25ter for additional information.
1.4.1 Conventions
In this manual, the following conventions are used to explain the AT commands.
<command>
The name of the command that is to be entered.
<parameter>
The parameter values that are defined for a certain command.
<CR>
The command line is terminated by the Carriage Return (or Enter key)
or ATS3 command.
<LF>
Line feed character or ATS4 command.
< > The term enclosed in angle brackets is a syntactical element. The
brackets do not appear in the command line.
[ ] Square brackets are used to indicate that a certain item is optional. For
example, sub-parameters of a command or an optional part of a response. The brackets do
not appear in the command line.
<Value> The default values of the supported parameters are indicated by using bold text
when presenting the value.
Other characters, including ‘?', parenthesis, etc., appear in commands and responses as
written.
The final result codes OK, ERROR, +CME ERROR: <err> and CMS ERROR:<err> (see
sections 1.3.3 AT Response Syntax and 1.4 Error Codes) are not listed under “Possible
Responses” for each AT command.
OK and ERROR are listed if these are the only possible responses.
1.4.2 AT Command Syntax
The AT standard is a line-oriented command language. Each command is made up of the
following three elements:
the prefix;
the body;
the termination character.
13/198 17-LXE 108 566 Uen
11

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet GR64.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
GR64Modem Integrators ManualSony
Sony
GR64AT Command ManualSony
Sony
GR64Wireless CPUWavecom
Wavecom
GR6953Self-oscillating Half-bridge Power ICgrenergy
grenergy

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar