Descripción (HX02-P - HX06-P) Current Transducer
Fabricantes LEM 
Logotipo LEM Logotipo



Hay una vista previa y un enlace de descarga de HX03-P (archivo pdf) en la parte inferior de esta página.


Total 2 Páginas

No Preview Available ! HX03-P Hoja de datos, Descripción, Manual

Current Transducer HX 02..06-P
IPN = 2 .. 6 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal Primary current
r.m.s. current measuring range
I
PN
(A)
I
P
(A)
2 ±6
3 ±9
4 ±12
6 ±18
Primary Conductor
Diameter x Turns
(mm)
0.5d x 30T
0.6d x 20T
0.7d x 15T
1.0d x 10T
Type
HX 02-P
HX 03-P
HX 04-P
HX 06-P
V
OUT
ROUT
R
L
VC
I
C
Vd
V
e
www.DataSheet4U.com
Output
voltage
@
±
I,
PN
R
L
=
10
k,
T
A
=
25°C
Output impedance
Load resistance
Supply voltage (± 5 %)1)
Current consumption
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
R.m.s. voltage for partial discharge extinction
at 10pC
Impulse withstand voltage, 1.2/50µs
±4
< 50
10
± 15
< ± 15
>3
1
6
V
k
V
mA
kV
kV
kV
Accuracy-Dynamic performance data
X
εL
VOE
VOH
εVOT
TC G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity error (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (-3 dB) 2)
< ± 1 % of IPN
< ± 1 % of IPN
< ± 40
mV
< ± 15
max. ± 1.5
± 0.1
3
50
mV
mV/K
%/K
µs
kHz
General data
TA Ambient operating temperature
TS Ambient storage temperature
m Mass
Min. internal creepage distance/clearance
Isolation material group
Standards
- 25 .. + 85 °C
- 25 .. + 85 °C
8g
5.5
mm
I
EN50178
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range 3x IPN
Power supply from ±12V to ±15V
Material according to UL94-V0
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Application Domain
Industrial
Notes : 1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN
2) Small signal only to avoid excessive heating of the magnetic cores
060920/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2
www.lem.com

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet HX03-P.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HX03-PCurrent Transducer HX 03~50-PLEM
LEM
HX03-P(HX02-P - HX06-P) Current TransducerLEM
LEM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar