파트넘버.co.kr BL6513 데이터시트 PDF


BL6513 반도체 회로 부품 판매점

Three-phase Active Energy Meter



SHANGHAI BELLING 로고
SHANGHAI BELLING
BL6513 데이터시트, 핀배열, 회로
Three-phase Active
BL0952A/BL6513/BL6511 Energy Meter
FEATURES
High accuracy, less than 0.1% error over a
dynamic range of 500:1
High stability during calibration, the fluctuation
of output CF is less than 0.1%.
Low drift, the gain variety is less than 0.1%
when input frequency changes from 45Hz to 65Hz
Single 5V Supply, Static Power 25mW(typical),
Power solution only with Resistor & Capacitor can be
adopted.
The Low Frequency Output (F1, F2) can drive
motor directly;
The High Frequency Output (CF) can be used in
calibration and data processing.
Selectable between the arithmetic sum of the
three-phase active energies and the absolute value
sum of these energies.
Measure positive active power and negative
active power.
Anti-Fault, the Logic Output REVP indicates a
Potential Miswiring or Negative Power for each
phase.
On-chip Creep Protection.
On-chip Power Supply Monitoring.
On-chip Reference 2.42V ± 8%,with External
Overdrive Capability.
SOP24 package.
Interrelated patents are pending
GENERAL DESCRIPTION
The BL0952A/BL6513/BL6511 is the chief IC of
the three-phase electrical meter and a high accuracy
energy measurement IC. With low power design,
static power is only 25mW. Based on the features such
as superior accuracy, high stability and simple
peripheral circuit, the BL0952A/BL6513/BL6511 is
compatible with 3-phase 3-wire and 3-phase 4-wire
configurations.
BL0952A/BL6513/BL6511 is based on digital
signal processing. BL0952A/BL6513/BL6511 can
measure positive active power and negative active
power; can select the way to calculate the sum of the
three-phase active powers, between the arithmetic
sum and the absolute value sum.
The high frequency output CF can be used in
calibration and data processing. The low frequency
outputs F1 and F2 can be used to drive a pulse-motor
or an electromechanical counter. In this way, the
power can be measured and the energy can be
recorded.
The internal phase matching circuitry ensures
that the current and voltage channels are phase
matched.An internal no-load threshold ensures that
the BL0952A/BL6513/BL6511 does not exhibit any
creep when there is no load.
The BL0952A/BL6513/BL6511 consider
emphatically the need of stability during calibration,
the measure data of mass products show that the
output pulse ripple of CF is less than 0.1%.
System Diagram Block
http://www.belling.com.cn
Fig.1 Functional block diagram
-1-
Total 1 Pages
4/21/2009


BL6513 데이터시트, 핀배열, 회로
BL0952A/BL6513 Three-phase Active
Energy Meter
PIN FUNCTION DESCRIPTION
Pin No.
1
Mnemonic
CF
Description
High frequency calibration logic output. The output frequency is
proportional to the average active power.
2 DGND This provides the ground reference for the digital circuitry .
3
4
5,6
7,8
9,10
11
12
VDD
REVP
IAP,IAN;
IBP,IBN;
ICP,ICN
AGND
REF
Power supply. This pin provides the supply voltage for the digital
circuitry. The supply voltage should be maintained at 5V ± 5% for
specified operation.
This logic output will go logic high when negative power is detected on
any of the three phase inputs, i.e., when the phase angle between the
voltage and the current signals is greater than 90°.
Analog inputs for current channel. These inputs are fully differential
voltage inputs with maximum differential input signal levels of
±500mV
This pin provides the ground reference for the analog circuitry.
This pin provides access to the on-chip voltage reference. The on-chip
reference has a nominal value of 2.42V ± 8% and a typical temperature
coefficient of 30ppm/°C. An external reference source may also be
connected at this pin.
13,14,
15,16
17
VN,VCP
VBP,VAP
ADDSEL
Analog inputs for the voltage channel. This channel is intended for use
with the voltage VBP, VAP transducer and is referenced as the voltage
channel in this document. These inputs are single-ended voltage inputs
with maximum signal level of ±500mV with respect to VN for
specified operation.
The logic input is used to select the way the three active energies from
the three phases are summed. This offers the designer the capability to
do the arithmetic sum of the three energies (ADDSEL logic High) or
the sum of the absolute value (ADDSEL logic low).
18
19
20
21,22
23,24
SCF
CLKIN
CLKOUT
S0,S1
F1,F2
Select Calibration Frequency. This logic input is used to select the
frequency on the calibration output CF.
Master clock for ADCs and digital signal processing. An external clock
can be provided at this logic input.3.58MHz
A crystal can be connected across this pin and CLKIN as described
above to provide a clock source.
These logic inputs are used to select one of four possible frequencies
for the digital-to-frequency conversion. This offers the designer greater
flexibility when designing the energy meter.
Low Frequency Logic Outputs. F1 and F2 supply average real power
information. The logic outputs can be used to directly drive
electromechanical counters and two-phase stepper motors.
http://www.belling.com.cn
-2-
Total 2 Pages
4/21/2009




PDF 파일 내의 페이지 : 총 13 페이지

제조업체: SHANGHAI BELLING

( shanghai )

BL6513 data

데이터시트 다운로드
:

[ BL6513.PDF ]

[ BL6513 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


BL6511

Three-phase Active Energy Meter - SHANGHAI BELLING



BL6512

With phase-phase metering chip output - SHANGHAI BELLING



BL6513

Three-phase Active Energy Meter - SHANGHAI BELLING



BL6514

Phase active power metering chip - SHANGHAI BELLING