파트넘버.co.kr ADE7763 데이터시트 PDF


ADE7763 반도체 회로 부품 판매점

Single-Phase Active and Apparent Energy Metering IC



Analog Devices 로고
Analog Devices
ADE7763 데이터시트, 핀배열, 회로
www.DataSheet4U.com
Single-Phase Active and Apparent
Energy Metering IC
ADE7763
FEATURES
High accuracy; supports IEC 61036/60687, IEC62053-21, and
IEC62053-22
On-chip digital integrator enables direct interface-to-current
sensors with di/dt output
A PGA in the current channel allows direct interface to
shunts and current transformers
Active and apparent energy, sampled waveform, and current
and voltage rms
Less than 0.1% error in active energy measurement over a
dynamic range of 1000 to 1 at 25°C
Positive-only energy accumulation mode available
On-chip user programmable threshold for line voltage surge
and SAG and PSU supervisory
Digital calibration for power, phase, and input offset
On-chip temperature sensor (±3°C typical)
SPI®-compatible serial interface
Pulse output with programmable frequency
Interrupt request pin (IRQ) and status register
Reference 2.4 V with external overdrive capability
Single 5 V supply, low power (25 mW typical)
GENERAL DESCRIPTION
The ADE77631 features proprietary ADCs and fixed function
DSP for high accuracy over large variations in environmental
conditions and time. The ADE7763 incorporates two second-
order, 16-bit Σ-∆ ADCs, a digital integrator (on Ch1), reference
circuitry, a temperature sensor, and all the signal processing
required to perform active and apparent energy measurements,
line-voltage period measurements, and rms calculation on the
voltage and current channels. The selectable on-chip digital
integrator provides direct interface to di/dt current sensors such
as Rogowski coils, eliminating the need for an external analog
integrator and resulting in excellent long-term stability and
precise phase matching between the current and the voltage
channels.
The ADE7763 provides a serial interface to read data and a
pulse output frequency (CF) that is proportional to the active
power. Various system calibration features such as channel
offset correction, phase calibration, and power calibration
ensure high accuracy. The part also detects short duration, low
or high voltage variations.
The positive-only accumulation mode gives the option to
accumulate energy only when positive power is detected. An
internal no-load threshold ensures that the part does not exhibit
any creep when there is no load. The zero-crossing output (ZX)
produces a pulse that is synchronized to the zero-crossing point
of the line voltage. This signal is used internally in the line cycle
active and apparent energy accumulation modes, which enables
faster calibration.
The interrupt status register indicates the nature of the interrupt,
and the interrupt enable register controls which event produces
an output on the IRQ pin, an open-drain, active low logic output.
The ADE7763 is available in a 20-lead SSOP package.
FUNCTIONAL BLOCK DIAGRAM
AVDD
PGA
V1P
ADC
V1N
TEMP
SENSOR
RESET
DVDD DGND
INTEGRATOR
MULTIPLIER
dt
LPF2
WGAIN[11:0]
HPF1
IRMSOS[11:0]
APOS[15:0]
ADE7763
CFNUM[11:0]
PGA
V2P
V2N
ADC
Φ

PHCAL[5:0] LPF1
2.4V
4k
REFERENCE
x2
VRMSOS[11:0]
x2
VAGAIN[11:0]
DFC
CF
CFDEN[11:0]
VADIV[7:0]
%%
WDIV[7:0]
REGISTERS AND
SERIAL INTERFACE
ZX
SAG
AGND
REFIN/OUT
CLKIN CLKOUT
DIN DOUT SCLK CS IRQ
1U.S. Patents 5,745,323; 5,760,617; 5,862,069; 5,872,469; others pending.
Figure 1.
Rev. A
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703 © 2004 Analog Devices, Inc. All rights reserved.


ADE7763 데이터시트, 핀배열, 회로
ADE7763
TABLE OF CONTENTS
Specifications..................................................................................... 3
Timing Characteristics..................................................................... 5
Absolute Maximum Ratings............................................................ 6
ESD Caution.................................................................................. 6
Terminology ...................................................................................... 7
Pin Configuration and Function Descriptions............................. 8
Typical Performance Characteristics ........................................... 10
Theory of Operation ...................................................................... 13
Analog Inputs.............................................................................. 13
di/dt Current Sensor and Digital Integrator ........................... 14
Zero-Crossing Detection........................................................... 15
Period Measurement .................................................................. 16
Power Supply Monitor ............................................................... 16
Line Voltage Sag Detection ....................................................... 17
Peak Detection ............................................................................ 17
Interrupts..................................................................................... 18
Temperature Measurement ....................................................... 19
Analog-to-Digital Conversion.................................................. 19
Channel 1 ADC .......................................................................... 20
Channel 2 ADC .......................................................................... 22
Phase Compensation.................................................................. 24
Active Power Calculation .......................................................... 25
Energy Calculation..................................................................... 26
Power Offset Calibration ........................................................... 28
REVISION HISTORY
10/04—Data Sheet Changed from Rev. 0 to Rev. A
Changes to Period Measurement Section ..................................16
Changes to Temperature Measurement Section........................19
Change to Energy-to-Frequency Conversion Section..............28
Update to Figure 61 .......................................................................29
Energy-to-Frequency Conversion............................................ 28
Line Cycle Energy Accumulation Mode ................................. 30
Positive-Only Accumulation Mode ......................................... 30
No-Load Threshold.................................................................... 30
Apparent Power Calculation..................................................... 31
Apparent Energy Calculation ................................................... 32
Line Apparent Energy Accumulation...................................... 33
Energies Scaling.......................................................................... 34
Calibrating an Energy Meter .................................................... 34
CLKIN Frequency ...................................................................... 43
Suspending Functionality.......................................................... 44
Checksum Register..................................................................... 44
Serial Interface ............................................................................ 44
Registers........................................................................................... 47
Register Descriptions ..................................................................... 50
Communication Register .......................................................... 50
Mode Register (0x09)................................................................. 50
Interrupt Status Register (0x0B), Reset Interrupt Status
Register (0x0C), Interrupt Enable Register (0x0A) ............... 52
CH1OS Register (0x0D)............................................................ 53
Outline Dimensions ....................................................................... 54
Ordering Guide .......................................................................... 54
Change to Apparent Energy Calculation Section .....................32
Change to Description of AEHF and VAEHF Bits ...................52
4/04—Revision 0: Initial Version
Rev. A | Page 2 of 56




PDF 파일 내의 페이지 : 총 30 페이지

제조업체: Analog Devices

( analogs )

ADE7763 data

데이터시트 다운로드
:

[ ADE7763.PDF ]

[ ADE7763 다른 제조사 검색 ]




국내 전력반도체 판매점


상호 : 아이지 인터내셔날

전화번호 : 051-319-2877

[ 홈페이지 ]

IGBT, TR 모듈, SCR, 다이오드모듈, 각종 전력 휴즈

( IYXS, Powerex, Toshiba, Fuji, Bussmann, Eaton )

전력반도체 문의 : 010-3582-2743



일반적인 전자부품 판매점


디바이스마트

IC114

엘레파츠

ICbanQ

Mouser Electronics

DigiKey Electronics

Element14


관련 데이터시트


ADE7760

Energy Metering IC - Analog Devices



ADE7761

Energy Metering IC - Analog Devices



ADE7761A

Energy Metering IC - Analog Devices



ADE7761B

Energy Metering IC - Analog Devices



ADE7762

Polyphase Energy Metering IC - Analog Devices



ADE7763

Single-Phase Active and Apparent Energy Metering IC - Analog Devices



ADE7768

Energy Metering IC - Analog Devices



ADE7769

Energy Metering IC - Analog Devices