Panasonic |
FAL6F
Features
• Operating Temperature: -10°C — +60°C (65% RH)
• Storage Temperature: -40°C — +75°C (65% RH)
• Bearing Type: Hydro Wave
• Optional third lead wire signal (Locked rotor alarm sensor)
Lead Wire
All lead wires are 275 mm in
length ± 15 mm. (bare wire
10mm. ± 5mm.)
UL 1007 AWG26
Housing: Plastic:
(PET, PBT, ABS)
Size
109.1 x 109.1 x 28.1
(4.31 x 4.31 x 1.11)
Weight
250 grams (8.82 ounces)
Case Quantity
40 per box
28.1
13.8 5
3-ø4.5
ø65.8
97.0
91.5
49.5
+ (red)
- (black)
10
275
DiorefcRtiootnation
All dimensions in mm.
(2) (24.1) (2)
Basic Data (nominal at room temperature)
53.6 R3
109.1
for tapping screws
(2-JIS class 2: ø3x14)
Conversion Factors
1 mm H2O = 9.8 PA
1 m3/min = 35.313 CFM
FAL6F12LL
Rated
Voltage
(V)
12
Operating
Voltage
(V)
7 — 13.8
Rated
Current
(mA)
Rated
Input
(W)
280 3.36
Nominal
Speed
(r/min)
Maximum
Air Flow
(m3/min) (CFM)
Maximum
Air Pressure
(mmH2O) (Pa)
Noise
(dB-A)
2100 0.53 18.7 11.25 176.5 40.0
FAL6F12LH
12 7 —13.8 500 6.00 2550 0.65 23.0 18.00 110.3 45.0
FAL6F24LL
24 14—27.0 155 3.72 2100 0.53 18.7 11.50 193.2 40.0
FAL6F24LH
24 14—27.0 295 7.08 2550 0.67 23.7 19.70 112.8 45.0
26
FAL6F
Characteristics
300 30
FAL6F12LL
6000
200 20
100 10
0
300 30
13.8V
4000
12V
10.2V
2000
7V
0.5 1.0 1.5 (m3/min)
12
Q Air Flow
(CFM)
FAL6F12LH
6000
200 20
100 10
0
300 30
200 20
100 10
13.8V
4000
12V
10.2V
2000
7V
0.5 1.0 1.5 (m3/min)
25 50
Q Air Flow
(CFM)
FAL6F24LL
27.0V
24V
20.4V
14V
6000
4000
2000
0
300 30
200 20
100 10
0.5 1.0 1.5 (m3/min)
12
Q Air Flow
(CFM)
FAL6F24LH
27.0V
24V
20.4V
14V
6000
4000
2000
0 0.5 1.0 1.5 (m3/min)
25 50
Q Air Flow
(CFM)
P— Q
N— Q
25
27
|