ETC |
PRECISION 2.5 VOLT MICROPOWER
VOLTAGE REFERENCE
ISSUE 2 - FEBRUARY 1998
ZR25D
DEVICE DESCRIPTION
The ZR25D uses a bandgap circuit design to
achieve a precision micropower voltage
reference of 2.5 volts. The device is available
in a small outline SOT23 surface mount
package, ideal for applications where space
saving is important.
The ZR25D design provides a stable voltage
without an external capacitor and is stable
with capacitive loads. The ZR25D is
recommended for operation between 50µA
and 5mA and so is ideally suited to low
power and battery powered applications.
Excellent performance is maintained to an
absolute maximum of 25mA, however the
rugged design and 20 volt processing allows
the reference to withstand transient effects
and currents up to 200mA. Superior
switching capability allows the device to
reach stable operating conditions in only a
few microseconds.
FEATURES
• Small outline SOT23 package.
• No stabilising capacitor required
• Typical TC 30ppm/°C
• Typical slope resistance 0.4Ω
• ± 3%, 2% and 1% tolerance
• Industrial temperature range
• Operating current 50µA to 5mA
• Transient response, stable in less than
10µs
• Alternative package options available
APPLICATIONS
• Battery powered and portable
equipment.
• Metering and measurement systems.
• Instrumentation.
• Test equipment.
• Data acquisition systems.
• Precision power supplies.
SCHEMATIC DIAGRAM
VR
Gnd
4-161
ZR25D
ABSOLUTE MAXIMUM RATING
Reverse Current
25mA
Forward Current
25mA
Operating Temperature -40 to 85°C
Storage Temperature
-55 to 125°C
Power Dissipation (Tamb=25°C)
SOT23
330mW
ELECTRICAL CHARACTERISTICS
TEST CONDITIONS (Unless otherwise stated) Tamb=25°C
SYMBOL PARAMETER
CONDITIONS
LIMITS
TOL. UNITS
%
MIN TYP MAX
VR
Reverse Breakdown Voltage IR=150µA
2.475 2.5 2.525 1
V
2.45 2.5 2.55 2
2.425 2.5 2.575 3
IMIN Minimum Operating Current
IR Recommended Operating
Current
25 50
0.05
5
µA
mA
TC †
RS §
ZR
Average Reverse Breakdown
Voltage Temp. Co.
Slope Resistance
IR(min) to
IR(max)
Reverse Dynamic Impedance IR = 1mA
f = 100Hz
IAC= 0.1 IR
30 90
0.4 2
0.3 0.8
ppm/°C
Ω
Ω
EN
Wideband Noise Voltage
IR = 150µA
f = 100Hz to
10kHz
45
µV(rms)
†
TC
=
(VR(max)−VR(min)) x 1000000
VR x (T(max)−T(min))
Note: VR(max) - VR(min) is the maximum
deviation in reference voltage measured
over the full operating temperature
range.
§
RS
=
VR
Change(IR (min) to IR
IR (max) − IR (min)
(max))
4-162
60
50
40
30
20
10
0
0.2
TA=T8A5=T°2AC=5-°4C0°C
0.6 1.0 1.4 1.8 2.2
Reverse Voltage (V)
2.6
Reverse Characteristics
|