Toshiba Semiconductor |
TOCP172−□□B
OPTICAL FIBER WITH FIBER OPTIC CONNECTORS
TOCP172− B
OPTICAL FIBER WITH FIBER OPTIC
CONNECTORS FOR DIGITAL
AUDIO USE
Unit: mm
l Fiber optic connectors conform to the JEITA
proposed standerds RC−5720.
l Simplex type
l APF (970 / 1000µm)
1. Maximum Ratings (Ta = 25°C)
Characteristics
Storage Temperature
Operating Temperature
Between Fiber and Connector
Tension
Optical Fiber
Bending Radius
Ratings
−40 to 70
−20 to 70
19.6
49
Min 25
Unit
°C
°C
N
N
mm
2. Optical Characteristics (Ta = 25°C)
Characteristics
Transmission Loss
Test Condition
λp = 660nm, Measured by fiber
length 50m
Min Typ. Max Unit
― ― 400 dB / km
1 2001-07-26
TOCP172−□□B
3. Precautions for Operation
(1) The maximum ratings are the limit values which should not be exceeded when using this product. All
of these values must be within the defined range. If the maximum ratings, are exceeded the deviced
characteristics may not be recoverable and, in extreme cases, permanent damage to the product may
result.
Care should be taken not to exceed the maximum ratings when using this product.
(2) Care should be taken not to drop heavy objects onto the optical fiber cables.
(3) When connecting or disconnecting the optical fiber with fiber optic connector, be sure to hold the fiber
optic connector. Do not hold the optical fiber cable when connecting or disconnecting.
(4) When inserting the fiber optic connector into the fiber optic transmitting/receiving module, be sure to
follow the correct fitting alignment.
(5) Keep the end face of the optical fiber with fiber optic connector clean. If contaminated, wipe it gently
with tissue paper.
(6) When bending the optical fiber cable to install it, note that the recommended bending radius is six to
ten times longer than the minimum bending radius.
(7) −□□ indicates the length and the unit of length of the optical fiber of the optical fiber with fiber optic
connector or optical fiber products. The length of the optical fiber is the distance from one end of fiber
optic connector to the other end. The minimum fiber length is 0.2m.
EX. TOCP172−1MB
Unit of length
C: cm
M: m
Length
2 2001-07-26
|