Intersil Corporation |
Data Sheet
HI-506A, HI-507A, HI-508A, HI-509A
June 1999 File Number 3143.2
16-Channel, 8-Channel, Differential
8-Channel and Differential 4-Channel,
CMOS Analog MUXs with Active
Overvoltage Protection
The HI-506A, HI-507A, HI-508A and HI-509A are analog
multiplexers with active overvoltage protection. Analog input
levels may greatly exceed either power supply without
damaging the device or disturbing the signal path of other
channels. Active protection circuitry assures that signal
fidelity is maintained even under fault conditions that would
destroy other multiplexers. Analog inputs can withstand
constant 70VP-P levels with ±15V supplies. Digital inputs will
also sustain continuous faults up to 4V greater than either
supply. In addition, signal sources are protected from short
circuiting should multiplexer supply loss occur. Each input
presents 1kΩ of resistance under this condition. These
features make the HI-506A, HI-507A, HI-508A and HI-509A
ideal for use in systems where the analog inputs originate
from external equipment, or separately powered circuitry. All
devices are fabricated with 44V dielectrically isolated CMOS
technology. The HI-506A is a single 16-Channel multiplexer,
the HI-507A is an 8-Channel differential multiplexer, the
HI-508A is a single 8-Channel multiplexer and the HI-509A is
a differential 4-Channel multiplexer. If input overvoltage
protection is not needed the HI-506/507/508/509
multiplexers are recommended. For further information see
Application Notes AN520 and AN521.
Features
• Analog Overvoltage . . . . . . . . . . . . . . . . . . . . . . . . 70VP-P
• No Channel Interaction During Overvoltage
• Maximum Power Supply . . . . . . . . . . . . . . . . . . . . . . . 44V
• Fail Safe with Power Loss (No Latch-Up)
• Break-Before-Make Switching
• Analog Signal Range . . . . . . . . . . . . . . . . . . . . . . . . ±15V
• Access Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500ns
• Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . 7.5mW
Applications
• Data Acquisition Systems
• Industrial Controls
• Telemetry
Ordering Information
PART
NUMBER
HI1-0506A-2
TEMP. RANGE
(oC)
-55 to 125
PACKAGE
28 Ld CERDIP
HI1-0506A-5
0 to 75
28 Ld CERDIP
HI1-0506A-8
-55 to 125
28 Ld CERDIP
+ 160 Hour Burn-In
HI3-0506A-5
0 to 75
28 Ld PDIP
HI1-0507A-8
-55 to 125
28 Ld CERDIP
+ 160 Hour Burn-In
HI3-0507A-5
0 to 75
28 Ld PDIP
HI1-0508A-7
0 to 75
16 Ld CERDIP
+ 96 Hour Burn-In
HI1-0508A-8
-55 to 125
16 Ld CERDIP
+ 160 Hour Burn-In
HI3-0508A-5
+0 to 75
16 Ld PDIP
HI1-0509A-2
-55 to 125
16 Ld CERDIP
HI1-0509A-5
0 to 75
16 Ld CERDIP
HI1-0509A-8
-55 to 125
16 Ld CERDIP
+ 160 Hour Burn-In
HI3-0509A-5
0 to 75
16 Ld PDIP
PKG.
NO.
F28.6
F28.6
F28.6
E28.6
F28.6
E28.6
F16.3
F16.3
E16.3
F16.3
F16.3
F16.3
E16.3
1 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143 | Copyright © Intersil Corporation 1999
HI-506A, HI-507A, HI-508A, HI-509A
Pinouts
HI-506A (CERDIP, PDIP)
TOP VIEW
HI-507A (CERDIP, PDIP)
TOP VIEW
+VSUPPLY 1
NC 2
NC 3
IN 16 4
IN 15 5
IN 14 6
IN 13 7
IN 12 8
IN 11 9
IN 10 10
IN 9 11
GND 12
VREF 13
ADDRESS A3 14
28 OUT
27 -VSUPPLY
26 IN 8
25 IN 7
24 IN 6
23 IN 5
22 IN 4
21 IN 3
20 IN 2
19 IN 1
18 ENABLE
17 ADDRESS A0
16 ADDRESS A1
15 ADDRESS A2
+VSUPPLY 1
OUT B 2
NC 3
IN 8B 4
IN 7B 5
IN 6B 6
IN 5B 7
IN 4B 8
IN 3B 9
IN 2B 10
IN 1B 11
GND 12
VREF 13
NC 14
28 OUT A
27 -VSUPPLY
26 IN 8A
25 IN 7A
24 IN 6A
23 IN 5A
22 IN 4A
21 IN 3A
20 IN 2A
19 IN 1A
18 ENABLE
17 ADDRESS A0
16 ADDRESS A1
15 ADDRESS A2
HI-508A (CERDIP, PDIP)
TOP VIEW
A0 1
ENABLE 2
-VSUPPLY 3
IN 1 4
IN 2 5
IN 3 6
IN 4 7
OUT 8
16 A1
15 A2
14 GND
13 +VSUPPLY
12 IN 5
11 IN 6
10 IN 7
9 IN 8
HI-509A (CERDIP, PDIP)
TOP VIEW
A0 1
ENABLE 2
-VSUPPLY 3
IN 1A 4
IN 2A 5
IN 3A 6
IN 4A 7
OUT A 8
16 A1
15 GND
14 +VSUPPLY
13 IN 1B
12 IN 2B
11 IN 3B
10 IN 4B
9 OUT B
2
|