DataSheet.es    


PDF CV2201 Data sheet ( Hoja de datos )

Número de pieza CV2201
Descripción Web tension measuring amplifier
Fabricantes Erhardt Leimer 
Logotipo Erhardt Leimer Logotipo




1. CV2201






Hay una vista previa y un enlace de descarga de CV2201 (archivo pdf) en la parte inferior de esta página.


Total 12 Páginas

No Preview Available ! CV2201 Hoja de datos, Descripción, Manual

Description U
Web tension measuring amplifier
CV 2201
1. Safety instructions
2. Function
3. Transport
4. Assembly
5. Installation
6. Commissioning
7. Troubleshooting / repair
8. Disassembly
9. Wiring Diagram
10. Technical data
2
3
3
4
4
5
9
10
10
12
EN
BEA--250059-EN-03
Free Datasheet http://www.datasheet4u.com/

1 page




CV2201 pdf
Web tension measuring amplifier CV 2201
Make earth and ground connections as shown in the wiring dia-
grams. See also EMC leaflet.
6. Commissioning
6.1 Measuring roller
NOTICE
The measuring rollers must be mounted free of mechanical stress and
move freely.
6.2 Safety barriers
R 40
NOTICE
In conjunction with safety barriers, the bridge voltage UB must be ad-
justed from 10 V DC to the maximum using the potentiometer R40
(right stop).
BEA--250059-EN-03
U 5/12
Free Datasheet http://www.datasheet4u.com/

5 Page





CV2201 arduino
9.1 Outputs
Web tension measuring amplifier CV 2201
The web tension is available in three different signals:
– Filter output UFilter (0 to ±10 V/10 mA, rise time 2 s) for
instruments.
– Direct output UDirect (0 to ±10 V/10 mA, rise time 5 ms) for fast
measured value acquisition and for downstream control circuits.
– Current output IDirect (0 to 20 mA or 4 to 20 mA, rise time 5 ms) for
measured value transmission over longer distances.
Sliding switch in position 1: 4 to 20 mA
Sliding switch in position 2: 0 to 20 mA (works setting)
NOTICE
Make sure that the load (current sensing resistor) does not exceed a
value of 600 Ohm!
The current output is only active with a positive voltage on the amplifi-
er's input.
Should the load cell output a negative signal voltage, the connections
for the bridge supply voltage +UB and -UB are to be swapped.
BEA--250059-EN-03
U 11/12
Free Datasheet http://www.datasheet4u.com/

11 Page







PáginasTotal 12 Páginas
PDF Descargar[ Datasheet CV2201.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
CV2201Web tension measuring amplifierErhardt Leimer
Erhardt Leimer
CV2201highly-programmable Image Cognition ProcessorsCogniVue
CogniVue
CV2201ValveETC
ETC
CV2202highly-programmable Image Cognition ProcessorsCogniVue
CogniVue

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices